Special messages
When starting the program and the door is not closed properly,
cdo
will
appear (Close door).
When starting the program and something is wrong with the water level
switches,
HLE
(high level),
LLE
(low level) or alternating
SLE - tilt
(safety level) will appear.
When one of the required temperatures was not reached during the program,
1tE, 2tE, 3tE
or
4tE
will appear at the end.
When one of the required water levels was not reached during the program,
HLE
(high level),
LLE
(low level) or alternating
SLE - til
t (safety level)
will appear at the end.
Extra switches and buttons. (Option)
Button adding water
With this button the water level in the tub will rise for as long as you press the
button.
Button drain water
With this button the water level in the tub will fall for as long as you press the
button.
Switch no high spin
By turning this switch to the right, high spin is executed as low spin.
Switch lowered water level
By turning this switch to the right, you can lower the water level in case of a
smaller wash-load. This can save time, water and energy.
Opening the door in
case of an emergency
When you want to open the door in case of an emergency (power breakdown,
deficiencies, etc...) remove the service panel (A) at the bottom and pull the left
suspended ring (B) while you press the red button on the doorhandle and open
the door.
p
p
p
p
p
p
Important:
Before opening the door, be sure there is no water left in the tub, and that
the drum has come to a complete stop.
p