Programming mode
4
FrEE==XX
= The maximum of segments available for programming
You can program a maximum of 160 segments.
Press " E ".
End
= End of this program segment
Press " NO " to proceed automatically to the next program segment (transition to "
XX.id YY
").
YY
stands for the next program segment number.
Press " E " to put an end to the program.
Tu XXX
= Tumble
This will be executed with a frequency of 6 sec. wash action and 9 sec. stop time. In case of frequency controlled
machines, the speed will be equivalent to the lowest programmed speed in that program.
Select the tumble time using X,X,X
(from 30 to 999 sec.)
and press E to confirm.
If no tumbling is required, 0 can be selected. There will then be a waiting time of 1 minute at the end of the
program.
ALArm.XXX
Here, the alarm can be activated again.
Select the duration of the alarm signal using X,X,X
(between 0 and250 seconds)
.
This option is only displayed if
ALArm
was selected during the preprogramming
.
If " 999 " was selected, the signal will be activated until the door is opened.
Data.XXXX
The new " checksum" is displayed for a few seconds at the end of programming. Then it proceeds to "
StArt
".