3
Water drain
The machine is equipped with a drain valve with 6/4" outer diameter (50 mm). This
drain valve should be connected to the drain by means of the drain elbow which
is delivered with the machine.
p
p
p
The diameter of the main drain should be adapted to the water flow and the
number of machines. It should be sufficient to handle at least 80L/min. per
machine.
It is necessary to connect the main drain at least on one side to an open air-
brake to allow ventilation.
When the main drain has not been sufficiently deodorized, every machine
should be installed seperately with a deodorizer.
In case of machines with
electrical heating two seperate connections
should always be used. One for the motor circuit, one for the heating.
After connection, check the
spin direction
. The cylinder must spin in the
direction of the arrow
, showed on the sticker on the door window
(
clockwise
).
A wrong spin direction can damage the motor, and can also cause water
to spurt from the soap dispenser.
In case of
wrong spin direction:
switch the terminal clamps of the motor
circuit R and S of the connecting cable.
p
p
Main power connection
p
Machine with steam heating or boiler fed machine
without additional electrical heating
Value of mains fuses:
Motor circuit:
220V 3AC
380V 3AC + N
16A
16A
Motor
Motor
Heating
Machine with electrical
heating
Value of the mains fuses:
Motor circuit:220V 3AC380V 3AC + N
16A
16A
Heating: 220V 3AC 380V 3AC + N
12kw
----
25A
15 kw
50A
25 A
18 kw
50 A
32 A
21 kw
----
40 A
24 kw
----
40 A