background image

This  laser  product  is  built  per  customer’s  specifications  and  sold  solely  as  a  component  (or  a 
module) for incorporation into other equipment. The purchaser assumes responsibility to comply 
with US FDA21 CFR 1040 with regard to the use of this laser and its introduction into commerce. 

LASER APERTURE 

AVOID EXPOSURE - LASER RADIATIONIS EMITTED 

OUT OF THIS APERTURE 

DANGER

 

VISIBLE/INVISIBLE LASER RADIATION 

AVOID DIRECT EXPOSURE TO BEAM 

Wavelength(nm) MaxPower(mW) 

532 

10 

CLASS IIIb LASER PRODUCT 

Model No.  

Serial No

 

Manufactured   

OEM PRODUCT

.

 

This product as stand-alone unit does 

not comply with safety regulations. 

For system integration only 

Model No.  
Serial No  
Manufactured.  

Sources for additional information and assistance on laser safety: 

CDRH-Radiological Health Program 
Office of Communication, Education and Radiation Programs 
Center for Devices and Radiological Health 
Food and Drug Administration 
10903 New Hampshire Avenue W066-4613 
Silver Spring, MD 20993 USA 
Tel: 1-800-638-2041, Fax: 1-301-847-8149 
[email protected] 

Laser Institute of America 
13501 Ingenuity Drive, Suite 128 
Orlando, FL 32826 USA 
Toll-Free: 1-800-345-2737 
Tel: 1-407-380-1553, Fax: 1-407-380-5588 
www.lia.org 

313 Enterprise Drive Plainsboro, NJ 08536

 

 

Tel: +1 (732) 

230-1601

 

  

Web: 

www.ipslasers.com

 

290020438-B 

(2021/01/14)

 

Page 

3

 

of 

5

 

Copyright 2021 IPS Lasers

 

Summary of Contents for BWG-532-OEM

Page 1: ...313 Enterprise Drive Plainsboro NJ 08536 Tel 1 732 230 1601 Web www ipslasers com 290020438 B 2021 01 14 Page 1 of 5 Copyright 2021 IPS Lasers Instruction Manual Single Frequency Lasers BWG 532 OEM ...

Page 2: ...ath of the beam Scattering the beam from a reflective surface is very damaging to eyes or skin 5 Do not wear rings metal watch bands or jewelry 6 Turn the power off preventing stray reflections from occurring either between experiments and when moving the laser for another application 7 Point the laser beam at a specific target 8 If possible have an enclosed path for the laser beam 9 Designate a s...

Page 3: ...lone unit does not comply with safety regulations For system integration only Model No Serial No Manufactured Sources for additional information and assistance on laser safety CDRH Radiological Health Program Office of Communication Education and Radiation Programs Center for Devices and Radiological Health Food and Drug Administration 10903 New Hampshire Avenue W066 4613 Silver Spring MD 20993 US...

Page 4: ...er beam output power level The output voltage range is 0 to 5 Volts This is maximum level of power output for a typical 50 mW laser corresponding to voltage range 0 4 0 6VDC The output impedance is 100 ohms 3 Installation 3 1 The laser head mounting plate should be coated with as thin as possible layer and evenly distributed thermal material such as thermal grease and mounted in the best contact p...

Page 5: ...tween the supplied control voltage and the laser output power within the Min and Max range 4 8 To ensure the performance of the laser and safety of the personnel always set pin 7 to High and pin 8 to Low before turning laser beam on Always allow sufficient time eg 5 minutes for the laser to reach its thermal equilibrium 4 9 Power off sequence Set the voltage of pin 8 to zero before powering off th...

Reviews: