7

10kVA/8kW

50A max.

220VAC

45A

290 x 600 x 642

36

15kVA/12kW

75A max.

220VAC

68A

300 x 600 x 742

42

20kVA/16kW

100A max.

220VAC

91A

300 x 600 x 742

42

Electric

Electric

Electric

Electrical

al

al

al performance

performance

performance

performance

Input

Model

Voltage

Frequency

Power Factor

Single phase

5K

Single-phase

40Hz-70Hz

>0.98 (Full load)

Single phase

6K/10K

Single-phase

40Hz-70Hz

>0.98 (Full load)

Three-phase

10KL/15KL/ 20KL

Three-phase

40Hz-70Hz

>0.95 (full load)

Output

Voltage

regulation

Power

factor

Frequency tolerance

Distortion

Overload capacity

Current

crest ratio

±

1%

0.8lag

Synchronized 46~54Hz

in Line mode(AC mode)

±

0.1% of normal

frequency in Battery

mode.

THD<3%

Full load

(linear

load)

105%

125% load

transfers to bypass

mode

after

60s,125%

150%

load transfers to

bypass after 30s.

3:1

maximum

Operating

Operating

Operating

Operating environment

environment

environment

environment

Temperature

Humidity

Altitude

Storage temperature

0

~40

20%~90%

<1000m

-15

~40

Note: if the UPS is installed or used in a place where the altitude is above than

1000m

1000m

1000m

1000m

,

the output power must be derated in use, please refer to the following :

 

Altitude

M

 

1000 

1500 

2000 

2500 

3000 

3500 

4000 

4500 

5000 

Derating power 

100% 

95% 

91% 

86% 

82% 

78% 

74% 

70% 

67% 

Summary of Contents for IP Compact Series

Page 1: ... Best of online in a compact product www ipower re Applications UPS Online IP COMPACT Available in 1 6 KVA ...

Page 2: ...tility utility power power power power supplied supplied supplied supplied in in in in Line Line Line Line mode AC mode AC mode AC mode AC mode mode mode mode 11 3 1 2 3 1 2 3 1 2 3 1 2 Turn Turn Turn Turn on on on on the the the the UPS UPS UPS UPS with with with with no no no no utility utility utility utility power power power power supplied supplied supplied supplied in in in in Battery Batter...

Page 3: ...ers and Peripherals are thus powered entirely by the UPS In the event of power failure the maintenance free batteries power the inverter This manual is applicable to the following models 1 The 6KS is a standard model with inbuilt battery hereinafter called 6KS 2 The 6KL is a long backup time model which is able to connect with the external battery bank hereinafter called 6KS 3 The 10KS is a standa...

Page 4: ...e Front and Back View of 6KVA single phase Front and Back View of 10KVA single phase L OUTPUT N L INPUT N L BYP BATTERY G PE LINE BYP RS232 EPO SNMP MAINTENANCE SWITCH PARALLEL PORT MUTE Front Panel Fan Manual Bypass Breaker Terminal AC Breaker Bypass Breaker Intelligent Slot Parallel Port RS232 EPO Emergency Power Off N INPUT OUTPUT BATTERY L L N L BYP MAINTENANCE SWITCH SNMP G PE LINE BYP MADE I...

Page 5: ... Bypass Breaker Terminal MUTE RS232 EPO PARALLEL PORT RS232 EPO Emergency Power Off Parallel Port C INPUT OUTPUT BATTERY N L N L BYP B A G PE LINE BYP C INPUT OUTPUT BATTERY N L N L BYP B A LINE BYP MAINTENANCE SWITCH PARALLEL PORT EPO RS232 SNMP M UTE Front Panel Terminal Manual Bypass Breaker Intelligent Slot RS232 EPO Emergency Power Off Parallel Port AC Breaker Bypass Breaker Fan ...

Page 6: ...d It will light with alarm when UPS has fault 6 Output indicator green It will light when the output is available 7 Inverter output indicator green It will light when the Inverter is working 8 Battery is working yellow It will light when battery supply power to UPS Screen is to view and choose the functions or items 9 ON OFF Press it longer than 1 second the UPS will start or turn off 10 Enter Thi...

Page 7: ...0kVA 8kW 10KS 50 60 176 276 Or 80 150 Vac 50A max 192 240VDC 10kVA 8kW 10KL 50 60 176 276 Or 80 150 Vac 50A max 192 240VDC 10kVA 8kW 3 phase10KS 50 60 304 478 Or 138 260Vac 50A max 192 240VDC 10kVA 8kW 3 phase10KL 50 60 304 478 Or 138 260Vac 50A max 192 240VDC 15kVA 12kW 3 phase15KL 50 60 304 478 Vac 75A max 192 240VDC 20kVA 16kW 3 phase20KL 50 60 304 478 Vac 100A max 192 240VDC Power rating Batte...

Page 8: ...olerance Distortion Overload capacity Current crest ratio 1 0 8lag Synchronized 46 54Hz in Line mode AC mode 0 1 of normal frequency in Battery mode THD 3 Full load linear load 105 125 load transfers to bypass mode after 60s 125 150 load transfers to bypass after 30s 3 1 maximum Operating Operating Operating Operating environment environment environment environment Temperature Humidity Altitude St...

Page 9: ...allation installation 1 1 1 1 Notes Notes Notes Notes for for for for installation installation installation installation 1 The UPS must be installed in a location with good ventilation far away from water inflammable gas and corrosive agents 2 Ensure the air vents on the front and rear of the UPS are not blocked Allow at least 0 5m of space on each side 3 Condensation to water drops may occur if ...

Page 10: ...cle may be burned and destroyed 5 Connect the input and output wires to the corresponding input and output terminals according to the following diagram 6 Note you must make sure that the input and output wires and the input and output terminals are connected tightly the protective earth ground wire refers to the wire connection between the equipment which consumes electric equipment and the ground...

Page 11: ...ON OFF position the UPS will charge the batteries automatically You can also use the UPS immediately without charging the batteries first but the backup time may be less than the standard value 11 If it is necessary to connect the inductance load such as a monitor or a laser printer to the UPS the start up power should be used for calculating the capacity of the UPS as its start up power consumpti...

Page 12: ...ttery first if you connect the cable to the UPS first you may encounter the hazardous of electric shock 2 To complete the connection by plugging the connector of the external battery cable into the external battery socket of the UPS Do not attempt to connect any loads to the UPS now You should connect the input power wire to the right position first And then set the breaker of the battery pack in ...

Page 13: ...e UPS will perform self diagnosis the Load Battery level LEDs will be turned on and then off one after another in ascending order then the INV LED will be turned off and Bypass LED will be turned on The UPS is working in Bypass mode 3 Upon completion of the above to turn it off output of electric current of the UPS is still present In order to cut off the output from the UPS simply cut off the uti...

Page 14: ...LEDs will be turned on and alarm will keep twice every second You should get rid of some unnecessary loads one by one to decrease the loads connected to the UPS less than 90 of its nominal power capacity Note Please follow the following steps to connect the generator Activate the generator and wait until the operation is stable before supplying power of the generator to the UPS be sure that the UP...

Page 15: ...creases and the battery voltage descends to the alarm level the buzzer will beep once every second to remind the users of in sufficient battery capacity and the UPS is soon going to shut down automatically Then the load operations should be carried out promptly and the loads should be eliminated one by one 3 2 3 2 3 2 3 2 3 3 3 3 Bypass Bypass Bypass Bypass mode mode mode mode The display panel in...

Page 16: ...S is operating in abnormal mode Please refer to the troubleshooting in section 6 for detail 3 2 3 2 3 2 3 2 5 5 5 5 Backup Backup Backup Backup time time time time for for for for the the the the standard standard standard standard model model model model The backup time of the long backup time model is dependent on the external battery pack capacity and the load level as well as other factors The...

Page 17: ...ve remote management of the UPS through internet intranet Please contact your local distributor for further information RS232 RS232 RS232 RS232 interface interface interface interface 1 The following are the descriptions and pin assignment of RS232 DB 9 port Baud rate 2400bps Data bit 8 bit Ending bit 1bit Parity bit None DB 9 pin assignment backup backup backup backup time time time time of of of...

Page 18: ...es dry contact closure signal OPEN or CLOSE Following are the pin assignment and the descriptions of AS400 card PIN1 UPS failure normally open active close PIN2 summary alarmPIN3 ground PIN4 Remote shutdown PIN5 Common PIN6 Bypass active relay close PIN7 Battery low PIN8 UPS On relay close PIN9 Utility Power failure normally open active close RS232 RS232 RS232 RS232 Interface Interface Interface I...

Page 19: ...rmal conditions the battery life lasts 3 to 5 years In case if the battery is found not in good condition earlier replacement should be made Battery replacement should be performed by qualified personnel Replace batteries with the same number and same type of batteries Do not replace the battery individually All the batteries should be replaced at the same time following the instructions of the ba...

Page 20: ... voltages Therefore before any maintenance and repairs work is carried out switch off the breaker of the battery pack or disconnect the jumper wire of connecting between the batteries 8 Batteries contain hazardous voltage and current Battery maintenance such as the battery replacement must be carried out by qualified personnel 6 6 6 6 Trouble Trouble Trouble Trouble shooting shooting shooting shoo...

Page 21: ...INVERTER short circuit Check the inverter part I N V V O L T L O W Inverter voltage low Check the inverter I N V V O L T H I G H Inverter voltage high Check the inverter I N V O V E R L O A D Inverter voltage overload Check the inverter B U S V O L T O V E R BUS over voltage Check the bus B U S V O L T U N D E R BUS under voltage Check the bus I N V O V E R T E M P Inverter over temperature Check ...

Page 22: ...ttery Battery anode and cathode connection in reverse Checking and reconnect Fans stop running Fans failed or board of fan damaged Contact with technician for repair UPS not start when turn on UPS Switch failed Check switch Power supply board failed Contact with technician for repair UPS no output when there is no mains Battery switch didn t turn on or failed Check switch Battery capacity is not e...

Page 23: ...ut fuse of charging board are failed Buzzer alarming for a long time FAULT light is bright Heat sink of inverter is over temperature Check if the heat dissipation is good or not UPS internal failed Contact with technician 键入文档的引述或关注点的摘要 您可将文本框放置在文档中的任何位置 可 使用 文本框工具 选项卡更改重要引述文本框的格式 ...

Reviews: