Page 28
-2 0
0
2 0
4 0
6 0
Ambient temperature
Recommended Engine Oil Type
8 0
1 00
1 2 0
-2 8 .9
°F
°
C
-1 7 .8
-6 .7
4 .4
1 5 .6
2 6 .7
3 7 .8
4 8 .9
1 0W-3 0
5 W-3 0 Full Synthetic
1 0W-4 0
5 W-3 0
Air Filter Maintenance
Change Engine Oil
Change engine oil per maintenance schedule.
If you are using your generator under extremely dirty
or dusty conditions, or in extremely hot weather,
change the oil more often.
CAUTION
Risk of burns. Allow engine to cool
before draining oil or coolant. Failure to
do so could result in death of serious
injury.
WARNING
NOTE:
Please use an approved container to catch and
recycle the used oil.
If contaminated or deteriorated oil is used or the
quantity of the engine oil is not sufficient, engine
damage will result and its life will be greatly
shortened.
Maximum oil capacity: 27.4 fl.oz (0.7L)
Check the engine oil level before each use or every 8
hours of operation.
1. Place the generator on a level surface and allow
the engine to cool for several minutes.
2. Turn knob and remove the oil access cover.
3. With a damp rag, clean around the oil dipstick.
4. Remove the oil dipstick.
5. Wipe the dipstick clean, then screw dipstick into
filler neck. Remove the dipstick and verify that
the oil level is within safe operating range.
6. If low, add recommended engine oil incrementally
and recheck until the level is between the L and H
marks on the dipstick.
DO NOT
overfill. If over the
full mark on the dipstick, drain the oil to reduce the
oil level to the full mark.
7. Replace the oil dipstick and hand-tighten.
H
L
1. With the help of another person, place the generator
on an elevated platform, such as a table or work
bench.
2. Unscrew the knob of the oil access cover (A) and
remove the cover from the side plate.
3. Place a suitable container (C) under the generator to
collect used oil.
4. Turn and remove the drainage plug (B) and allow the
oil to drain completely.
NOTE:
Drain the lubricant while the engine is still warm but not
hot. Warm lubricant will drain quickly and more
completely.
5. After draining the oil, recover the plug (B) and place
the oil drain pipe inside the unit.
6. The generator is in the horizontal position and
refilled. Operate the engine oil according to the
instructions in the inspection manual / the chapter of
adding engine oil in front of this manual.
7. Wipe out any spilled oil and reinstall the oil access
cover(A).
1. Unscrew the maintenance cover knobs to remove the
maintenance cover (A).
A
B
C
2. Remove knob (B) and air filter cover plate (C).
3. Remove the filter element(D).
4. If the filter element is dirty, wash it with warm
soap and clean water and dry it.