iPower GXS7100iRD Owner'S Manual Download Page 1

PORTABLE GENERATOR

Owner’s Manual

P/N: 32082-04705-03

Model:                                   
Serial:                                   
Date Purchased:                    

Model# 3222003 REV01

SAVE THIS MANUAL FOR FUTURE REFERENCE

DO NOT RETURN
TO STORE!
CALL US FIRST
855-888-3598
FOR SUPPORT

GXS7100iRD

Summary of Contents for GXS7100iRD

Page 1: ...BLE GENERATOR Owner s Manual P N 32082 04705 03 Model Serial Date Purchased Model 3222003 REV01 SAVE THIS MANUAL FOR FUTURE REFERENCE DO NOT RETURN TO STORE CALL US FIRST 855 888 3598 FOR SUPPORT GXS7100iRD ...

Page 2: ...ngine Generator 20 Select the Fuel Source Gasoline 21 Select the Fuel Source Propane LPG 21 Connecting Electrical Loads 22 Low Idle Switch 23 Stopping the Engine 23 Low Oil Shutdown 24 Do Not Overload Generator 24 Changing Fuels 25 Parallel Operation 25 Set up and Operation 25 Maintenance And Storage 27 Maintenance Schedule 27 Engine Maintenance 27 Engine Oil Level Check 27 Change Engine Oil 28 Ai...

Page 3: ...ime without notice Page 01 DEFINITIONS AND SYMBOLS DANGER Indicates a hazard which if not avoided will result in death or serious injury WARNING Indicates a hazard which if not avoided could result in death or serious injury NOTICE Indicates information considered important but not hazard related e g messages relating to property damage CAUTION Indicates a hazard which if not avoided could result ...

Page 4: ...ed according to the manufacturer s instruction Operate this product ONLY outside far away from windows doors and vents to reduce the risk of carbon monoxide gas from accumulating and potentially being drawn towards occupied spaces DO NOT run this product inside homes garages basements crawl spaces sheds or other partially enclosed spaces even if using fans or opening doors and windows for ventilat...

Page 5: ...irect exhaust away from occupied spaces CORRECT USAGE INCORRECT USAGE Example location to reduce risk of carbon monoxide poisoning Near any door window or vent Garage Basement Crawl Space Living Area Attic Entry Way Porch Mud Room Do not operate in any of the following locations ...

Page 6: ...create an explosion hazard When exchanging propane LPG cylinders be sure the cylinder valve is of the same type Always keep the propane LPG cylinder in an upright position Propane LPG will burn skin if it comes in contact with it Keep it away from skin at all times WHEN ADDING OR DRAINING FUEL Turn generator engine off and let it cool at least 2 minutes before removing gasoline cap Loosen cap slow...

Page 7: ...pplicable laws and electrical codes WHEN OPERATING THE GENERATOR DO NOT operate the generator inside any building carport porch mobile equipment marine applications or enclosure DO NOT tip the generator at angle which causes fuel to spill DO NOT move the generator when is running DANGER WHEN TRANSPORTING MOVING OR REPAIRING THE GENERATOR Transport move repair with fuel tank EMPTY or with fuel shut...

Page 8: ...or anything that could be caught in the starter or other rotating parts Starter and other rotating parts could entangle hands hair clothing or accessories Keep away from rotating parts failure to do so could result in death or serious injury Unintentional sparking could cause fire or electric shock resulting in death or serious injury DO NOT tamper with governor spring links or other parts to incr...

Page 9: ...his product to power medical devices or medical appliances Inform your electricity provider immediately if you or anyone in your household depends on electrical equipment to live Inform your electrical provider immediately if a loss of power would cause you or anyone in your household to experience a medical emergency Medical and Life Support Uses In case of emergency call 911 immediately WARNING ...

Page 10: ...e at 855 888 3598 with the unit model and serial number for any missing item Record model serial number and date of purchase on front cover of this munual for your own record NO 1 2 3 4 5 6 7 8 9 10 Qty 1 1 1 1 1 1 1 1 1 1 Item Description Oil Bottle 700ml Owner s Manual Quick Start Guide Spark Plug Wrench Screw Driver 30 AMP RV Adapter Flexible Screw on Funnel Propane LPG Hose with Regulator Batt...

Page 11: ... 10 11 7 9 8 1 2 4 5 3 1 Control Panel 2 Telescopic Handle 3 Romote Holder 4 Fuel Cap 5 Recoil Starter 6 Maintenance Cover 7 Support Leg 8 Engine Oil Access Cover 9 Muffler Spark Arrester 10 Wheel 11 Propane Inlet 6 Page 09 ...

Page 12: ...z Outlet NEMA L5 30R This receptacle can provide120 volt output up to 30 amps 10 Grounding Terminal To ground the generator 11 120V AC 20A Duplex Single Phase 60Hz Outlets 5 20R Each outlet is capable of carrying a maximum of 20 amps on a single outlet or a ombination of both outlets 12 Voltage Selector Switch To select 120 Volt or 240 Volt Turn generator off before switching voltages 15 CO Carbon...

Page 13: ... off the engine The engine will not start until the proper amount of oil is in the crankcase 5 Select Button Push this button to show the volage power fuel level frequency or total running time in LED Multi Meter 4 Overload Rest Button With Indicator Light The indicator light is green when theinverter is running under rated load The indicator light will turn to blinkingred or solid red when the ra...

Page 14: ...re with new remote control Press and hold the STOP button of the remote control fob the engine push button red light will start flashing and then it will stay on 1 Turn the battery switch to ON l position 2 Press and hold the remote set button for 3 5 seconds until the light of the engine push button light illuminates red Remote Set Button 3 Press and hold the START button of the remote control fo...

Page 15: ...above 60 F 16 C ambient temperature GXS7100iRD Model Number Starting Watts Running Watts Rated AC Voltage Rated DC Voltage Rated Frequency Phase Grounding System AC Engine Type Engine Displacement Starting System Low Oil Shutdown Oil Type Oil Capacity Spark Plug OEM Type Spark Plug Replacement Type Spark Plug Gap Valve Intake Clearance Valve Exhaust Clearance Voltage Regulation System Alternator E...

Page 16: ... DANS LA MAISON OU LE GARAGE MOVE TO FRESH AIR GET MEDICAL HELP IF SICK DIZZY OR WEAK WARNING ADVERTISSEMENT ADVERTENCIA TAMPERING WITH CO WATCH GUARD COULD RESULT IN HAZARDOUS CONDITION L ALTÉRATION DE WATCH GUARD CO PEUT ENTRAîNER DES CONDITIONS DANGEREUSES HACER ALTERACIONES CON WATCH GUARD CO PODRíA OCASIONAR CONDICIONES PELIGROSAS VOUS RETIRER À L AIR FRAIS CONSULTER UN MÉDECIN SI VOUS ÊTES M...

Page 17: ...n CO WATCH GUARD will detect the accumulation of carbon monoxide from other fuel burning sources such as engine powered tools used in the area of operation If another generator is used and the exhaust is pointed at a CO WATCH GUARD equipped generator the CO WATCH GUARD may initiate a shutoff due to rising carbon monoxide levels This is not a fault Hazardous carbon monoxide has been detected You mu...

Page 18: ...ck to see if generator is sitting at an angle that forces oil to shift Place on an even surface to correct this If engine fails to start the oil level may not be sufficient to deactivate low oil level switch Make sure the sump is completely full of oil The engine is equipped with a low oil shut off and will stop when the oil level in the crankcase falls below the threshold level 1 Place generator ...

Page 19: ... fuel hose or tank during storage Alcohol blended fuels called gasohol ethanol or methanol can attract moisture which leads to separation and formation of acids during storage Acidic gas can damage the fuel system of an engine while in storage To avoid engine problems the fuel system should be emptied before storage of 30 days or longer See the Long Term Storage section Never use engine or carbure...

Page 20: ...G cylinder equipped with an OPD overfilling prevention device valve DO NOT check for leaks with a lighted match or flame The propane cylinder valve should be fully closed when the generator is not in use or is running with gasoline The regulator hose assembly and cylinder valve must be inspected before each use for leaks or sign of damages All new cylinders must be purged of air and moisture prior...

Page 21: ...ite or similar activity as defined by NFPA 70 2020 NEC section 590 6 Connecting to a Building s Electrical System Connections to your home s electrical system must use a listed transfer switch installed by a licensed electrician The connection must isolate the generator power from the utility power and comply with all applicable laws and electrical codes NOTICE WARNING Shock hazard Failure to prop...

Page 22: ...tor hazards READ MANUAL BEFORE USE Only use OUTSIDE and far away from windows doors and vents WARNING DANGER Never use generator in wet or damp locations Never expose generator to rain snow water spray or standing water while in use Protect generator from all hazardous weather conditions Moisture or ice can cause a short circuit or other malfunction in the electric circuit Water contact with a pow...

Page 23: ...G 1 Connect the LPG gas hose to the propane fuel source Connect the small end of the LPG gas hose to the LPG inlet on generator and then snug with a wrench to prevent leakage 4 Turn the starting dial switch to ON position 5b Electric start Turn and hold the ENGINE START STOP switch for 5 seconds until the engine start 3 Turn the battery switch to ON l position when the Voltage Selector Switch in i...

Page 24: ...er than you can let go which could cause broken bones fractures bruises or sprains resulting in serious injury Connecting Electrical Loads This unit has been pretested and adjusted to handle its full capacity Before starting the generator disconnect all loads Apply load only after generator is running Voltage is regulated via the engine speed adjusted at the factory for correct output Re adjusting...

Page 25: ...or electric pump Allow the engine speed to stabilize before turning the switch to ON position If no load is present the generator speed RPM will drop to idle speed The generator will detect loads as they are applied and increase engine speed RPM To run the generator at maximum power and speed RPM push the LOW IDLE Switch to the OFF position Stopping the Engine 1 Turn off and remove entire electric...

Page 26: ... connected electrical devices To prolong the life of your generator and attached devices follow these steps to add electrical load 1 Start the generator with no electrical load attached 2 Allow the engine to run for several minutes to stabilize 3 Plug in and turn on the first item It is best to attach the item with the largest load first 4 Allow the engine to stabilize 5 Plug in and turn on the ne...

Page 27: ...ICE Fire and electrocution hazard Never connect or disconnect the parallel cord leads when a generator is running Do not parallel more than two generators Use only AIPOWER generators for paralleling WARNING 2a Gasoline to Propane LPG Fully open the Propane LPG cylinder knob 2b Propane LPG to Gasoline Make certain the cylinder knob is fully closed Connect the LPG hose to the propane fuel source Con...

Page 28: ...he instructions included with your parallel operation kit for proper installation and operation NOTE It is strongly recommended to plug in devices with the largest output first and the smallest output last to help prevent overloading the inverters Do not exceed maximum wattage rating of inverters parallel kit and receptacles 5 Start one of the generators and wait until the engine speed to stabiliz...

Page 29: ...ll value from the warranty the operator must maintain generator as instructed in this manual Some adjustments will need to be made periodically to properly maintain your generator All service and adjustments should be made at least once each season Follow the requirements in the Maintenance Shedule chart above ENGINE MAINTENANCE CAUTION To prevent accidental starting remove and ground spark plug w...

Page 30: ...ify that the oil level is within safe operating range 6 If low add recommended engine oil incrementally and recheck until the level is between the L and H marks on the dipstick DO NOT overfill If over the full mark on the dipstick drain the oil to reduce the oil level to the full mark 7 Replace the oil dipstick and hand tighten H L 1 With the help of another person place the generator on an elevat...

Page 31: ... generator Unplug battery charger from the wall outlet and generator control panel when generator is going to be used AC wall outlet Spark Plug Maintenance The spark plug must be properly gapped and free of deposits in order to ensure proper engine operation To check 1 Unscrew the knobs and remove the maintenance cover 2 Remove the spark plug cap B 3 Clean any dirt from around base of spark plug 4...

Page 32: ...the generator Water can enter the generator through the cooling slots and damage the generator windings Use a damp cloth to clean exterior surfaces of the generator Use a soft bristle brush to remove dirt and oil Use an air compressor 25 PSI 172 kPa to clear dirt and debris from the generator Cleaning the Spark Arrestor NOTE This product is equipped with a spark arrestor that has been evaluated by...

Page 33: ...he drain screw on the bottom of the carburetor float bowl 4 Place an appropriate gasoline container to catch the drained fuel 5 Loosen the float bowl drain screw and allow the fuel to drain from the drain tube Tighten the float bowl drain screw 6 Reinstall the maintenance cover DANGER Explosion and Fire Fuel and vapors are extremely flammable and explosive Store fuel in a well ventilated area Keep...

Page 34: ...and re crank engine 11 Contact customer service or authorized service center 12 Contact customer service or authorized service center 13 Contact customer service or authorized service center 14 Replace fuel filter Engine lacks power 1 Load is too high 2 Dirty air filter 3 Clogged or dirty fuel filter 4 Clogged or dirty spark arrester screen 5 Engine needs to be serviced 6 Bad fuel 17 Clogged or di...

Page 35: ... 9 10 10 11 7 2 6 3 4 16 107 108 8 5 40 42 41 32 35 36 37 38 31 39 33 34 21 25 24 27 29 27 30 23 17 18 19 20 22 28 28 23 23 26 23 24 1 43 55 56 59 61 54 58 57 60 58 57 62 64 49 52 53 51 44 45 46 47 48 50 65 66 97 98 99 96 90 91 92 90 91 92 93 93 87 95 93 101 103 102 67 68 63 69 70 72 71 75 80 85 86 83 88 89 93 94 90 91 92 78 81 88 79 88 73 76 73 100 84 5 105 106 104 ...

Page 36: ...lt M6 12 Screw Right cover plate assy Screw Cable handle trim cover Screw Limit stop Oil maintenance cover plate Switch knob NO 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 Qty 1 1 1 1 2 1 1 1 1 1 1 1 4 4 1 2 1 1 4 4 1 1 1 1 2 1 1 2 1 1 1 2 1 2 2 1 1 1 Part Number 34032 00298 00 20134 00330 00 30136 00074 00 30101 00398 00 34040 ...

Page 37: ... 00326 00 30101 00405 00 30117 00011 00 34024 00004 00 20114 06496 01 30111 00088 00 33013 00941 00 30111 00088 00 70009 00999 00 31034 00041 00 20033 00051 00 Description Clamp Carbon canister Hex flange nut M8 Hex flange bolt M6 12 Support bracket Support bracket Hex flange bolt M6 12 Screw Metal wire clip Fuel tank left cross member Hex flange bolt M6 12 Clip nut M5 Left shell assy Screw Switch...

Page 38: ...S L L C D e g a t l o v r o t a l u g e r r e i f i t c e r R B R B B S U B W B W L B 2 4 6 8 0 1 2 1 1 3 5 7 9 1 1 D E L l e l l a r a P s t e l t u o O Y Y l e v e l l e u F r o s n e s 0 1 A 6 h c t i w s l a i d g n i t r a t S N O F F O G I E S F G B W R G Y Y E K T A B h c t i w s y r e t t a B 2 1 6 5 4 7 9 8 0 1 1 1 2 1 3 a t a D r e t n e c R G W G R B A 0 2 R 0 2 5 R 0 3 5 L A 0 3 R 0 3 ...

Page 39: ... warranty will not cover repair when normal use has exhausted the lifetime of a part s or engine Installation and Maintenance this warranty does not cover improper or unauthorized assembly alteration modification or any other damage resulting from misuse or neglect Normal maintenance parts this warranty does not cover spark plugs air filters adjustments or other related service due to obstructions...

Page 40: ...uivalent packaging Improperly packaged returns will not be accepted Must have adequate packing for transportation Federal Law requires that all machines that utilize gasoline oil or other flammable liquids must be drained Completely Thoroughly prior to shipment Gas caps and oil plugs must be left off for 24 hours prior to shipping Please note liability for this violation of the law resides with th...

Page 41: ...Fontana CA 92337 USA Phone 855 888 3598 support a ipower com www a ipower com ...

Page 42: ... 1 Product Value for Price Paid Performance Features Product Appearance Warranty Ease of Maintenance Noise Level 5 HOW LIKELY ARE YOU TO RECOMMEND A iPOWER TO FAMILY OR FRIENDS Extremely Not Likely Likely at all 5 4 3 2 1 Privacy Statement A ipower is committed to respecting your privacy and to complying with the regulations regarding the protection of personal data The survey data we collect is f...

Page 43: ...Fontana CA 92337 USA Phone 855 888 3598 support a ipower com www a ipower com ...