Wiring Cat5/RJ-45 Cables

All Cat5/RJ-45 cables used in iPort IW installations must be wired according
to the T568A (“Straight-Through”) Standard with cables wired identically at
both ends.

To prepare Cat5/RJ-45 cables for iPort installations:

1. Pull the Cat5 wire through the wall between the desired locations.

2. Use a stripper or knife to strip about 1” of the cable jacket off each end

of the wire.

• Be careful not to nick any of the individual wires.

3. Untwist the wire pairs and spread them flat. Arrange them as shown in

Figure 3.

4. Trim the ends of the individual wires to ½” in length, making sure that

they are even with each other. Flatten the wires against each other, 
leaving no space between them.

5. Hold the RJ-45 connector clip-side down and insert the Cat5 wire ends

firmly into the connector. Make sure that all the wires are flat all the way to the very front of the connector.

6. Re-confirm that the color orientation matches the diagram and that cable jacket fits against the connector stop. 

7. Firmly crimp the RJ-45 connector with the crimp tool. Confirm that the connector is crimped firmly and that all the wires

are flat right up against the front of the connector. If even one of these wires is incorrect, cut the connector off the cable
and repeat steps 2 – 7 with a new RJ-45 connector.

Installation Preparation 

(all models)

The iPort features an integral Roto-Lock mounting system for quick mounting directly into existing walls. Once the hole is cut
and the cables have been run, you can install the iPort into the wall in a matter of seconds.

1. Determine the location for the iPort and the wall plate(s). Note that the unbalanced audio in IW-20/IW-21 systems and the 

unbalanced video in IW-21/IW-22 systems are designed for use in a local-zone system where the iPort wall plate and
audio/video equipment are located less than 30 feet from the iPort. 

2. Perform an obstruction survey to be certain that there are no studs, conduit, pipes, heating ducts, or air returns that will

interfere with the iPort.

Note: You can mount the iPort directly next to a wall stud on either side (see 

Step 8

, on page 8).

3. The iPort cut-out is 4” (102mm) wide x 5

9

/

16

” (141mm) high. There also must be at least 3½” (89mm) depth within the wall

cavity for the iPort and its connections.

4. Find the cut-out template provided in the iPort packaging. Position the template where the iPort is to be located and 

pencil an outline on the wall.

• If you are unsure about obstructions, drill a small hole in the center of the outline and insert a coat hanger wire into the

hole to feel around for possible obstructions.

5. Cut the opening using a drywall saw.

6

I n s t r u c t i o n   M a n u a l

Figure 3: Cat5/RJ-45 Cable Wiring

Summary of Contents for IW-20

Page 1: ...Instruction Manual IW 20 IW 21 IW 22 ...

Page 2: ...mplate 1 Instruction manual IW 21 System Capabilities Delivers local zone unbalanced audio up to 30 feet from the iPort Optional Balanced Audio Upgrade Kit part number 70130 required for distributed audio distances up to 500 feet from the iPort Delivers unbalanced video output iPod video content only not program metadata via RJ 45 connector up to 30 feet from the iPort Optional Balanced Video Upgr...

Page 3: ...trol of most iPod iPhone audio functions when in general control mode Optional iPort remote available part number 70030 black 70032 white Integrated RS 232 control enables two way communication including iPod program metadata and control of the iPod iPhone via compatible control systems Please visit iportmusic com for a complete list of compatible control systems Charges the iPod iPhone while it i...

Page 4: ...ud Avoid installing the iPort in a location that is in direct sunlight a portion of the day as it can interfere with IR operation Selectable Features IW 21 and IW 22 only IMPORTANT Before installing the iPort you need to select the audio output mode the video output type and the default control mode The selector switches are located on the iPort main circuit board as shown in Figure 1 1 Select the...

Page 5: ...wall plate Unbalanced video wall plates use the included 5 foot RJ 45 to female RCA cable and require a male to male RCA cable not included Balanced video wall plates require that the installer make a Cat5 RJ 45 cable as described on page 6 The VIDEO connection transmits unbalanced or balanced NTSC video to the video wall plate Supplemental Power Connector IW 21 IW 22 only Removable 4 Pin screw co...

Page 6: ...e connector off the cable and repeat steps 2 7 with a new RJ 45 connector Installation Preparation all models The iPort features an integral Roto Lock mounting system for quick mounting directly into existing walls Once the hole is cut and the cables have been run you can install the iPort into the wall in a matter of seconds 1 Determine the location for the iPort and the wall plate s Note that th...

Page 7: ... RJ 45 Cables section on page 6 The audio Cat5 RJ 45 cable pin assignment is 3 Plug the Cat5 cable into the AUDIO connector on the iPort and the RJ 45 jack on the wall plate as shown in Figure 4 4 Install the wall plate into an electrical box in the room near the audio system CAT5 RJ 45 CABLE UP TO 30 FEET NOT INCLUDED RJ 45 Audio Connector To RJ 45 Connector on Wall Plate Rear To AUDIO Connectors...

Page 8: ...ck screws on the iPort utility box as shown in Figure 5 The Roto Lock clamps will automatically rotate into position behind the wall and begin clamping the iPort When you notice resistance on the two screws the iPort has been clamped successfully IMPORTANT NEVER over tighten the Roto Lock screws 8 If there is a wall stud up against one side of the utility box that prevents one Roto Lock clamp from...

Page 9: ...ection on page 6 The audio Cat5 RJ 45 cable pin assignment is 9 To Video Wall Plate Supplemental Power GND 15V GND 15V VIDEO RJ 45 Video Connector Supplemental Power Connector not used RJ 45 Audio Connector To RCA Connector on Wall Plate Rear To RJ 45 Connector on Wall Plate Rear To AUDIO Connectors To VIDEO Connector To Composite Video Input To PWR Connector STEREO RCA CABLE NOT INCLUDED COMPOSIT...

Page 10: ...ote The Roto Lock system can accommodate a maximum wall material thickness of 13 8 9 Hand tighten the two Roto Lock screws on the iPort utility box as shown in Figure 5 on page 8 The Roto Lock clamps will automatically rotate into position behind the wall and begin clamping the iPort When you notice resistance on the two screws the iPort has been clamped successfully IMPORTANT NEVER over tighten t...

Page 11: ...ay Be sure to insert the cards all the way into their connectors Installing the Balanced Audio Circuit Card 1 Locate the balanced audio PCB Connector and BALANCED UNBALANCED audio switch on the iPort backplane circuit board see Figure 8a The backplane circuit board is red and it is located at the rear of the iPort chassis utility box 2 Slide the BALANCED UNBALANCED audio switch UP to the Balanced ...

Page 12: ... location and run a standard male to male RCA cable through the wall from the iPort location to the unbalanced video wall plate location as shown in Figure 10 page 13 The balanced audio wall plate can be located up to 500 feet from the iPort the unbalanced video wall plate can be located up to 30 feet from the iPort Find a location for the balanced audio wall plate that is near the audio system co...

Page 13: ...O 500 FEET NOT INCLUDED RJ 45 Video Connector RJ 45 Audio Connector To RJ 45 Connector on Wall Plate Rear To AUDIO Connectors To RS 232 Connector To VIDEO Connector To Composite Video Input To PWR Connector STEREO RCA CABLE NOT INCLUDED COMPOSITE VIDEO CABLE NOT INCLUDED To Wall Outlet To Control System IR Output To Control System RS 232 Output iPort rear iPort Balanced Audio Wall Plate iPort Unba...

Page 14: ...al Electrical Code 8 Use a stereo RCA audio cable to connect the balanced audio wall plate s AUDIO connectors to a source input on the audio system as shown in Figure 10 page 13 9 For IR control systems Use a 3 5mm cable mono or stereo to connect the balanced audio wall plate s IR connector to the IR control output of a com patible IR control system Please go to iportmusic com for a complete list ...

Page 15: ...in the correct positions see Selectable Features page 4 and attach the iPort face to the utility box as shown in Figure 6 page 8 Slide the face all the way into the box until it fits snugly into place 16 Plug the included DC power supply into the PWR connector on the wall plate and into a wall outlet as shown in Figure 10 page 13 Adjusting the iPort for Different iPod Models The iPort is compatibl...

Page 16: ...ious album playlist and chapter repeat and shuffle Extensive long distance control of the iPod iPhone from a compatible IR control system is also available through the IR connector on the balanced audio wall plate Go to iportmusic com for a complete list of compatible control systems Extensive two way long distance communication and control of the iPod iPhone is also available from compatible RS 2...

Page 17: ...n the iPod is un docked from the iPort the indicator illuminates DIM for 2 minutes then turns OFF The user can change these settings to any of three illumination levels bright medium and dim via RS 232 or the iPort remote Always ON Mode The installer or user can defeat the 2 minute turn off function the indicator will operate as above but will not turn OFF after two minutes via RS 232 or the iPort...

Page 18: ...rights which vary from state to state Some states do not allow the exclusion of implied warranties or limitations of remedies so the above exclusions and limitations may not apply If your state does not allow disclaimer of implied warranties the duration of such implied warranties is limited to the period of iPort s express warranty _________________________________________________________________...

Page 19: ...19 iPor t IW 20 IW 21 IW 22 Instruction Manual Notes ...

Page 20: ...reserved iPort and Roto Lock are registered trademarks of Dana Innovations iPod and iPhone are trademarks or registered trademarks of Apple Inc Due to continuous product improvement all specifications are subject to change without notice For the latest iPort product information go to www iportmusic com ...

Reviews: