background image

 

 

 

MANUAL 

• Subject to alteration! Version: 18

th

  August 2020 

 

 

068-14986 

ipf electronic gmbh

 

 Rosmarter Allee 14 • 58762 Altena • Germany 

 Tel +49 2351 9365-0 • [email protected] 

 

www.ipf-electronic.com

 

 

 

 

5

 

 

 

Switching the analog characteristic curve 
 
 

     

Characteristic curve (as teached)

 

 

   

 

 

Characteristic curve inverted

→ …

 

 
 

 

 

 

 

 

Switching Auto-Detect / NPN / PNP 
 
 

     

Auto-Detect   

 

   NPN 

 

→ 

   PNP   

→ …

 

 
 

 

 

 

 

 

 

Switching the analog output 
 
 

     

Analog output voltage

 

 

 

 

 

→  

 

Analog output current

 

 

→ …

 

 
 

 

 

 

 

Button Q

A

 > 

press

 

10s

, until the green 

and yellow LEDs are 

blinking alternately 

green LED is blinking 

yellow LED is on 

 

wait 10s  

 

 

 

Button Q

A

 press quickly  

green LED in blinking 

yellow LED is off 

 

wait 10s 

 

 

 

Button Q > 

press

 

13s

, or connect 

Control with  

L+ > 13s until the 

green and the 

yellow LED are 

blinking 

simultaneously 

Green and 

yellow 

LED are blinking 

simultaneously 

 

wait 10s  

 

 

 

Button Q press 

quickly or 

connect control 

with L+ 

green LED is 

blinking 

 

wait 10s 

 

 

 

Button Q press 

quickly or 

connect control 

with L+ 

yellow LED 

is blinking 

 

wait 10s  

 

 

 

Button Q

A

 > 

press

 

13s

, until the green 

and the yellow LED 

are blinking 

simultaneously 

green LED is 

blinking 

 

wait 10s  

 

 

 

Button Q

A

 press quickly 

yellow LED 

is blinking 

 

wait 10s  

 

 

 

Reviews: