background image

Teach process for window function 

1. Connect  for  a  period  of  time  between 6 and 10 seconds  the  white  wire (PIN2) with the 

operating voltage. The LED flashes with approx. 2.5Hz.

2. Release the connection. The yellow LED now flashes with a frequency of 1Hz.
3. Place the object to be detected at the switching point at long distance.
4. Connect  the  white  wire (Pin2) for  at  least  1  second  with  the  operating  voltage. The yellow LED 

will flash with a frequency of 2.5Hz, if the value is stored.

5. Release the connection.
6. Place  the  object  to  be  detected  at  the  switching  point  at small distance. The distance to the 

previous taught switching point has to be at least 5mm!

7. Reconnect  the  white  wire  (Pin2)  for  at  least  1  second  with the operating voltage. The yellow 

LED will flash with a frequency of 5Hz, if the value is stored.

8. The  teach  process  is  completed.  The  sensor's  output  functions  as  normally  open contact, i.e. it 

is active, when an object is detected between the two switching points. The taught value is stored 

and is also available after switching the sensor off and on again.

9. If the LED flashes with a frequency of 6Hz, the teach process has failed. The object could not be 

detected, beacuse it was e.g. placed beyond the detection range. In this case, the teach process has 

to be repeated.

Note regarding the switching function:

 

If  you  want  the  output  to  function  as  normally  closed  contact  during  mode  „window  function“,  i.e. 

beyond  the  taught  window,  place  the  object  to  be  detected  first  (3)  at  the  switching point 

at small distance  – and then (6)  at the switching point at long distance.  

Note regarding the switching output: 

The  terms  „normally  open  contact“  and  „normally  closed  contact“  used  in  this  manual  refer  to  the 

wiring  diagram  A  (PNP).  If  the  device  is  connected  according  to  wiring  diagram  B  (NPN),  the switching 

output functions inversely.  

Reset to the factory setings

1.  Connect  for  more  than  10  seconds  the  white  wire  (PIN2)  with  the  operating  voltage.  The LED 

flashes  with  approx.  0.5Hz.

After  releasing  the  connection  the sensor functions with the factory settings (switching distance approx. 

65mm, sensing).

MANUAL • Subject to alteration! Version: 

August  2019

 

ipf electronic gmbh • Rosmarter Allee 14 • 58762 Altena 

 Tel +49 2351 9365-0 • Fax +49 2351 9365-19 

 [email protected] • www.ipf-electronic.com 