8. AUTOMATE OC29 X.LITE PROCAP
OC29 X.Lite ProCap provides the option to start, stop, and save recordings automatically in order to localise errors that
are difficult to reproduce. Additionally, you may select if the status of the control signals should be written to the im-
ages.
In this case, there are a variety of basic settings and different activation options.
8.1.
Basic selection, signal sources and trigger mode
1. Activation of the trigger mode with selection of the signal source
2. Detailed selection of communication via Ethernet
Beckhoff ADS
connection to a Beckhoff SPS via the ADS interface
Siemens Snap7
connection to a Siemens SPS via Snap7
B&R PVI
connection to a B&R SPS via the PVI manager
3. Mit The recording is saved in the selected directory immediately after the recording ends by activating a
save option After saving, the system is ready fort he next signal reception, communication remains active!
If "Direct saving" is active, no save option can be selected as the recording is immediately saved to the hard
disc!
4. Two modes can be chosen between:
Start recording trigger
... after receiving the start signal, recording is started for the set duration (see chap-
ter 6.2).
Stop ring buffer trigger
... a ring buffer is started by clicking on (5) <Start communication> which is ended
by the trigger signal.
5. If "Direct saving" is active, "Start recording trigger" mode is automatically selected since no ring buffer re-
cordings are possible in this mode!
6. Communication is started using this button, it starts reading the signals!
7. For communication via Ethernet, the selected connection is first established
1
2
3
4
5
MANUAL • Subject to alteration! Version:
September 2019
ipf electronic gmbh • Rosmarter Allee 14 • 58762 Altena
│
Tel +49 2351 9365-0 • Fax +49 2351 9365-19
│
[email protected] • www.ipf-electronic.com
11