MANUAL
• Subject to alteration! Version: November 2021
ipf electronic gmbh
│
Rosmarter Allee 14
•
58762 Altena
• Germany
│
Tel +49 2351 9365-0 • [email protected] •
3
3 For safe operation
The operating parameters of the LED luminaire specified on the type plate must correspond to the supply
parameters of the machine or the transformers.
Operate the luminaire only in the fastened state.
The luminaire must not be covered with tissues, foils, etc. under any
circumstances. Object distance from the luminaire at least 10cm.
Machines can emit voltage peaks due to various influences.
These voltage peaks
must be avoided when supplying power via machines
: Only use regulated 24V
DC switched-mode power supplies, not transformers with rectifiers, as these can
emit voltage peaks due to inductance.
Hot plugging should be avoided (connecting the luminaire to a power supply that is already connected to
the mains), as this can destroy the LED luminaire.
4 Safety information
Installation of electrical equipment may only be carried out by qualified electri-
cians.
Follow the five safety rules according to DIN VDE 1005.
Failure to do so may result in damage to the LED luminaire, as well as fire or
other hazards.
Danger of electric shock!
Disconnect before working on the device or load. En-
sure to disconnect all circuit breakers that supply dangerous voltages to the de-
vice or load, when doing so. Even when the device is switched off, the load is
not galvanically isolated from the mains.
Only use the device if it is completely free of faults, and with safety and aware-
ness in mind.
If warnings or symbols are attached to the luminaire, they must not be removed.
LED lighting systems can produce very intense radiation which, if used improp-
erly, can possibly damage the eyes.