MANUAL
– Subject to alteration! Version: August 2022
ipf electronic gmbh
│
Rosmarter Allee 14
-
58762 Altena
-
Germany │ Tel +49 2351 9365
-
0
-
info@ipf-
electronic.com
17
Specification of the analog input (AD/IO1 to AD/IO4)
•
Overload protection
•
Reverse polarity protected
•
Operational modes: voltage, current
Operational mode voltage
Operational mode current
Measuring range = 0 to 11 V
Dielectric strength = 30 V
Resolution = 12 bit Input resistance
= 122 k
Ω
Bandwidth = 1 kHz
Measuring range = 0 to 24
mA Max. Input current = 30
mA Resolution = 12 bit
Bandwidth = 1 kHz
5.1.4
Power supply
•
24 V ± 10 %
•
Max. Power consumption = 120 W
5.1.5
Ethernet 1 and Ethernet 2
o
10BASE-T/100BASE-TX according to IEEE 802.3u with HP Auto MDI/MDI-X
5.1.6
USB
•
USB1
and
USB2
o
Located on the front and bottom of the BY000002
o
Maximum power output = 2.5 W (500 mA)
o
USB2.0 supports Full-, High- and Low-Speed (480, 12 and 1.5 Mbit/s)
•
USB3
o
Micro USB port
o
Located on the front of the BY000002
o
Maximum power consumption = 6.5 W (1.3 A)
o
May vary depending on connected device and power supply. With an
active 24V power supply, the power consumption = 0.
o
USB2.0 supports Full-, High- and Low-Speed (480, 12 and 1.5 Mbit/s)
Note:
To access the USB2 and USB3 ports, you must flip up the protective flap on the
front panel
.