GB
DISPLAY ALARMS
BRUSH MOTOR CUTOUT
TRIPPED
The brush motor has overheated.
BRAKE
The parking brake is engaged or the drive motor has over-
heated.
STAND-BY
The driver detection microswitch is not detecting an operator.
RELEASE ACCELERATOR
Incorrect starting sequence. Release the accelerator pedal
when starting.
EEPROM 1 FAULT
Replace the display board.
DRIVE CONTROL BOARD
CUTOUT TRIPPED
The drive control board has overheated.
ACCELERATOR FAULT
There is a problem with the accelerator cable.
MAX. SPEED POTENTIOM
-
ETER FAULT
There is a fault in the maximum speed potentiometer cabling.
UNDERVOLTAGE FAULT
Check the batteries.
OVERVOLTAGE FAULT
Check the batteries.
RELAY FAULT
Replace the drive control board.
HPD
Check the accelerator pedal. Switch the machine off and back
on with the accelerator released.
MOSFET FAULT
Replace the drive control board.
EEPROM 2 FAULT
Replace the drive control board.
37