Integration of Legacy Autoscript Controllers with WP-IP
Legacy Autoscript controllers can be integrated within a WP-IP system. This enables users to keep
using existing controllers while upgrading to WP-IP from WinPlus. By using a serial to Ethernet
convertor, older devices can become part of an IP workflow.
Supported legacy Autoscript controllers are:
•
HC-1
: 5 button Desk top Hand Control
•
MFC
: Magno Foot Control
Used in isolation or incorporated into package MFC-PKG, which also includes MFC-D
•
WSC-REC
: Wireless Scroll Control Receiver Only (ROW)
Incorporated into package WSC which also includes WSC-RAT, and package WFC-PKG-ROW
which also includes WFC
•
WSC-REC-A
: Wireless Scroll Control Receiver Only (U.S.)
Incorporated into package WSC-A which also includes WSC-RAT-A, and package WFC-PKG-US
which also includes WFC-A
These controllers can be connected to the WP-IP application using a serial to ethernet convertor and
bespoke serial cable. This is supplied by Autoscript as a package part (SRL-IP).
Power: All legacy controllers require external power. The serial cable supplied in the package SRL-IP
passes power through the serial to Ethernet convertor to the controller. The package SRL-IP includes
an external PSU.
The SRL-IP convertor
always
requires its own PSU (included). It cannot be powered by PoE.
Parts List
•
PSU-HR:
DC Power supply with Hi-rose connector (PSU for legacy controllers)
•
A9009-5002:
SRL-CL: Legacy Autoscript Serial Controller Cable
•
G452-006:
Ethernet to serial convertor, single channel
Package Part
•
SRL-IP:
Legacy controller convertor package
Includes A9009-5002 + G452-006
Please Note: Autoscript legacy controllers have been tested with PoE injector model Lantronix
UDS1100. Compatibility with any other Serial to PoE convertors cannot be guaranteed.
For this package to be compatible you
must
use the Autoscript cable A9009-5002,
not
the Six-foot
DB9F-to-DB25M modem cable (Lantronix P/N 500-163).