Standby Mode 

If uSTART

®

 is in 

Run Mode

 and a vehicle’s battery charging system

 

has been inactive for more than 1 hour, 

uSTART

®

 will automatically enter 

Standby Mode 

in order to reduce energy consumption

.

 If at any time 

uSTART

®

 detects a significant, rapid change in the voltage level (as will occur during engine start), uSTART

®

 

will automatically return to 

Run Mode

 and support the engine cranking event. It is not safe to handle or work 

on uSTART™ when it is in 

Standby Mode.

 

Standby Mode

 is indicated by all LED’s being 

off

 while connected to battery power

.

 uSTART

®

 operation can 

be confirmed by noting the change to a 

solid

 

green LED 

upon engine start, indicating a return to 

Run 

Mode.

 

Jump Start Mode 

Jump Start Mode

 allows uSTART

®

 to charge up its ultracapacitors from a weak vehicle battery and provide 

power to jump start the vehicle.  

 

Jump Start Mode 

can be 

accessed through the uSTART App. The 

green LED

 will 

flash

 and the 

yellow 

LED

 

will 

flash

 as uSTART

®

 charges its ultracapacitors. After the charging period finishes, the 

green LED

 

will 

flash

 

and the 

yellow LED

 will light

 

solid

 

indicating that the vehicle is ready to be started. Start the vehicle 

immediately for best results. See the uSTART App User Manual for additional details. 

 

Fault Mode 

uSTART® has experienced an abnormal condition or fault, indicated by a 

solid red LED

. See the 

Troubleshooting section for more information.  

Bluetooth Connection 

uSTART is connected via Bluetooth when the 

blue LED

 is lit solid. See the uSTART App User Manual for 

more details (note that the blue LED may be difficult to see in bright locations, shading the status LED area 
may help with seeing it). 

Flow Charts 

The below flow charts can be utilized to move through the different modes of uSTART

®

 The flow charts are 

separated by mode and navigate through each mode separately. For example, if 

Run Mode 

is desired, use the 

Run Mode 

flow chart. 

 

Summary of Contents for uSTART uST12D1100G31-ISA

Page 1: ...Class 3 6 with 12V Operating System Table of Contents Model uST12D1100G31 ISA 1 Safety 2 Description 3 Feature Identification 3 Unpacking 3 Installation 4 Maintenance Mode 4 Mounting Location 4 Pre I...

Page 2: ...r additional information Do not connect in reverse polarity uSTART is protected from reverse polarity in Maintenance Mode but sparks and arcing will occur if a reverse polarity connection is attempted...

Page 3: ...of damage prior to unpacking Report any damage to the carton or the contents to the carrier immediately Retain all shipping materials until uSTART is fully inspected and determined to be operational...

Page 4: ...x is near the Diesel Particulate Filter After Treatment System or any part of the exhaust mount uSTART in a location far away from it or install heat shielding capable of preventing uSTART from experi...

Page 5: ...ery ies and uSTART in their appropriate locations When installing uSTART it is important to consider the battery hold down being used and how uSTART relates to any batteries being mounted with it uSTA...

Page 6: ...1 877 751 4222 Fax 607 433 9014 http www ioxus com sales ioxus com 2 21 2019 DOC 1 0004 Rev A 2017 Ioxus Inc All rights reserved 6 Wiring Diagrams Figure 2 Typical wiring diagram before uSTART instal...

Page 7: ...low LED indicates that it is in Maintenance Mode If uSTART is not connected to a battery it will still be in Maintenance Mode but the LEDs will be off If uSTART is not in Maintenance Mode when it is d...

Page 8: ...ultracapacitors from a weak vehicle battery and provide power to jump start the vehicle Jump Start Mode can be accessed through the uSTART App The green LED will flash and the yellow LED will flash as...

Page 9: ...Stadium Circle Oneonta NY 13820 Toll Free 1 877 751 4222 Fax 607 433 9014 http www ioxus com sales ioxus com 2 21 2019 DOC 1 0004 Rev A 2017 Ioxus Inc All rights reserved 9 Run Mode Figure 5 Run Mode...

Page 10: ...Circle Oneonta NY 13820 Toll Free 1 877 751 4222 Fax 607 433 9014 http www ioxus com sales ioxus com 2 21 2019 DOC 1 0004 Rev A 2017 Ioxus Inc All rights reserved 10 Maintenance Mode Figure 6 Mainten...

Page 11: ...m Circle Oneonta NY 13820 Toll Free 1 877 751 4222 Fax 607 433 9014 http www ioxus com sales ioxus com 2 21 2019 DOC 1 0004 Rev A 2017 Ioxus Inc All rights reserved 11 Jump Start Mode Figure 7 Jump St...

Page 12: ...ive heat shield may be worth installing between a heat source and the uSTART An environmental condition above 65 C 149 F will cause uSTART to enter Fault Mode in order to protect the product Prolonged...

Page 13: ...TART has detected an abnormal internal condition causing it to enter fault mode No LED s On 1 Standby Mode This is a normal condition uSTART will enter Run Mode automatically when the vehicle is start...

Reviews: