Page 3
FIXTURE
TSPL
LUMINAIRE HOUSING
STEP 2 -
MOUNTING THE P-320
STEP 3 -
INSTALLING THE TEST SWITCH PILOT LIGHT (TSPL)
RED
WHITE
NEUTRAL
120/277 LINE
UNSWITCHED
BLACK
YELLOW
YEL/BLK
BLU/WHT
BLUE
WHT/RED
EMERGENCY
BALLAST
A. Position the
P-320
in the fixture wireway and fasten securely through the Mounting Slots. If necessary, drill holes and
mount with sheet metal cutting screws (not provided).
B. Fully plug the
Quick Disconnect Harness
into the
P-320
Quick Disconnect Port. Inspect that the Harness is squarely
seated against the
P-320
housing.
C. Attach the flat wire tie holder to the fixture channel. Insert a wire tie into the wire tie holder and pull the wire tie tight
around the wires extending from the Quick Disconnect Harness. This will help prevent the Quick Disconnect Harness
from being disengaged. Inspect that the Quick Disconnect Harness is still fully plugged in to the
P-320
Port.
A. Locate a suitable location for the TSPL and cable that is at least 1” from the fixture lamps and is visible outside the fixture.
Drill or punch a 1/2” diameter hole in the fixture wall or wireway cover. Insert the TSPL into the hole so that the LED test
button/pilot light is located outside of the fixture.
B. Slide the TSPL Mounting Clip firmly to lock and secure the TSPL assembly.
DO NOT CONNECT THE TSPL PLUG AT THIS TIME
STEP 4 -
WIRING THE AC INPUT
COMPLETING INSTALLATION
A
A
B
B
C
P-320
The P-320 requires an
unswitched AC input
of
120/277 volts. Connect the
BLACK
wire to the
120/277 Line
, and the
WHITE
wire to the
Neutral
.
STEP 5 -
APPLY AC POWER AND
CONNECT THE TSPL
A.
Apply continuous AC power to the P-320
, then connect and fully engage the TSPL Connector to the P-320. Insure the
TSPL connector latch is properly seated in the recess slot on the P-320 housing.
Ensure that continuous AC power has
been applied to the P-320 before connecting the TSPL
, or you will begin to drain the P-320 batteries and may hinder
proper emergency operation.
B. Verify that the TSPL light is on, then mark the TSPL location on the fixture with the TSPL label.
Caution: fixture contains live wires during
this portion of installation. Use insulated
gloves and tools