Operation
8
❸
Protocol Setting. Move up/down the joystick, choose protocol, right move the joystick or press
ENT to confirm.
- - - -
Set protocol. This protocol must be the same
as the camera’s protocol.
Available Options
:
PELCO D/PELCO P
/VISCA
❹
Baud rate setting. Move up/down the joystick, choose baud rate, and right move the joystick or
press ENT to confirm.
- - - -
Set baud rate. This baud rate must be the
same as the camera’s baud rate.
Available Options
:
2400/4800/9600/19200
/38400
❺
Address Setting. Input number to set camera address (range from 0~255). Press ENT to
confirm
。
- - - -
Set the controller’s address, this address must
be the same as the camera’s address.
Available Options
:
0~255
❻
The controller can also batch program cameras in the system. It will set the same baud rate,
protocol for the 10 cameras next to the current one while the cameras’ address to be increased
by increment number sequentially. After step 5, press SHIFT to enter menu “INCREMENT:”
Input a number within 1~20, press ENT to confirm.
-
- - -
The address increment between two
sequential cameras. For example, the current
camera address is 1 and the increment is 2,
then the next camera address is 3.
Available options:
1~20
❼
After the camera setting is finished, the system will automatically return to the main menu
。
INCREMENT:
ADDRESS:1
BAUD RATE:2400
PROTOCOL:PELCO D