Maintenance Procedures – Battery Charging
39
Battery Charging with the CTEK XS7000
FOR PROPER FUNCTION OF THE THERMOPURE SYSTEM, ENSURE THE BATTERY IS
CHARGED EVERY DAY.
Settings are made by pressing the “MODE” button and stepping forward by pressing the
button one step at a time, releasing the button when the required mode is reached. After
approx .2 seconds, the charger activates the chosen mode. The select mode is saved in the
chargers memory and remains even when the charger is switched off.
Mode “Normal” (14.4v)
Normal setting for wet batteries.
Mode “RECOND” (15.7V, 1.5a 0.5 - 4h)
This mode is used to recondition very discharged batteries where stratified acid is expected
(High acid weight in bottom, low on top). Use this mode with care as it can cause some water
loss.
15.7V is normally not a problem for fast charging however do not operate the machine whilst
charging in this mode.
Summary of Contents for Zero PPB
Page 1: ...1 Operators Manual...
Page 5: ...Zero Weights Dimensions 5 Dimensions...
Page 7: ...Machine Component Identification 7 Component Identification...
Page 8: ...Machine Component Identification 8 Control Panel...
Page 10: ...Machine Component Identification 10 Zero System Filters Removed...
Page 13: ...Machine Component Identification 13 Filter Identification Zero PPB System...