System Operation
LITHIONICS BATTERY, CLEARWATER, FL 33765 USA | PH: 727.726.4204 | FAX: 727.797.8046 | WEB: LITHIONICSBATTERY.com
20
Powering the System On
Short press the Power switch for 1 second. The switch will illuminate once power is enabled. You may notice
an audible “thunk” noise of the internal contactor switching on. Check that there is voltage at the Power Terminals
with a voltmeter.
Powering the System Off
Long press the Power switch for 3 seconds. The switch will cease to illuminate once power is disabled. You
may notice an audible “thunk” noise of the internal contactor switching off. Check that there is 0V at the output
terminals with a voltmeter.
Charging
The charging device(s) connected to the Lithium Battery System must be programmed to the correct
parameters for the battery. Charging may be performed at any time the system is powered ON.
NOTE – The Lithium Battery System will disconnect power if the voltage, amperage, or temperature limits are exceeded
during charging. Only use a Lithionics Battery approved charging source. Please contact
Lithionics Battery for charger approval.