![ionGen XANTREX 3000 Installer'S Manual Download Page 10](http://html1.mh-extra.com/html/iongen/xantrex-3000/xantrex-3000_installers-manual_2087547010.webp)
Inverter Diagram
LITHIONICS BATTERY, CLEARWATER, FL 33765 USA | PH: 727.726.4204 | FAX: 727.797.8046 | WEB: LITHIONICSBATTERY.com
8
A warning label should be installed at the main AC panel to indicate that there is an
inverter in the system.
The inverter is provided with a ground relay that automatically connects the neutral
output to the chassis if no external AC supply is available. In an RV installation, the
inverter chassis must be connected the vehicle chassis ground (via the negative
distribution buss). The chassis grounding conductor must be sized not less than one size
smaller than the DC positive conductor and have a capacity such that the DC positive
fuse has an amperage rating not greater than 135% of the current rating of this
grounding wire.
When using an inverter sub panel, the inverter neutral cables must return to the
inverter sub panel and not the main AC panel.