 Digital Level Control 

Digital Level Control Switch

Patent pending

F

EATURES

1.  First of its kind, solid-state sensing technology 

with no moving parts.

2.  Space age design with no mechanical 

 

contact points.

3.  Multipoint sealing mechanism that supersedes 

single surface seals.

4.  Inverter rated for use with any battery 

 

back-up system.

5.  Standard piggy back connection for use with  

any pump.

6.  Suitable for sump and sewage applications.

P

IPE 

M

OUNTING 

B

RACKET 

(

OPTIONAL

)

1.  Determine bracket mounting position (Figure 

A).

2.  Mount bracket to Ion

®

 switch with screw already 

provided in Ion

®

 switch (Figure B).

3.  Mount Hose Clamp with switch around pipe 

at predetermined level. Cable should remain 

outside hose clamp (Figure C).

4.  Tighten hose clamp.

Note:

 

The Ion

®

 switch is available in 6” or 8.5” ranges. 

A 10” range is available for special applications. See 

chart for available ranges and cord lengths. The range 

of the switch is the distance between the On and Off 

levels. The Off level is at the bracket mounting screw 

of the switch. From this point, measure up either 6” or 

8.5”, depending on your switch’s range, to find the On 

level. Please refer to the Installation Drawing.

CAUTION: 

Bottom of switch should not be 

mounted lower than suction inlet of pump. 

When installing the Ion

®

 switch with the pipe mounted 

bracket be sure not to set the switch too low or too 

high on the pipe. The Ion

®

 must be installed above the 

inlet of the pump to prevent air-locking as shown in 

the installation drawing.

To  prevent  flooding  do  not  set  the  on  point  of  the 

switch higher than the top of the basin.

Model

Cord 

Range 

IN-006-010-10PA-B

10

6

IN-085-010-10PA-B

10

8.5

IN-006-020-10PA-B

20

6

IN-085-020-10PA-B

20

8.5

P

IGGY

-B

ACK

 I

NSTALLATION

Electrical outlet must not be located in pump pit. 

Electrical outlet voltage, piggy-back plug voltage and 

pump voltage must all be the same voltage.

DO NOT CUT plug off unit.

Ensure vent tube on plug is protected from moisture, 

dirt and insects and other items that could plug or 

block tube.

1.  Insert the Ion

®

 switch’s piggy-back plug into 

the outlet.

2.  Plug pump into piggy-back plug as (Figure E).

3.  Allow system to cycle to ensure proper 

installation.

Please note this product may not work in 

conjunction with other controllers.
Note:

 The Ion

®

 switch does not operate like a standard 

pressure switch. There are no contacts to wear out, 

so when pressure is applied, there will not be a click.

Summary of Contents for WC33

Page 1: ...This system is not intended for use in hazardous locations per NFPA 70 National Electric Code Do not pump flammable liquids Consult factory for optional equipment rated for hazardous location use WARN...

Page 2: ...the floor and you must unplug the pump or make any adjustments Pump Servicing Note Automatic thermal overload protects the sealed in oil motor Running dry may overheat the motor and activate the over...

Page 3: ...s 1 Inlet in pump base may be clogged Remove pump and clean out openings 2 Impeller or volute openings may be plugged or partially plugged Remove pump and clean out 3 Pump impeller may be partially cl...

Page 4: ...6 or 8 5 depending on your switch s range to find the On level Please refer to the Installation Drawing CAUTION Bottom of switch should not be mounted lower than suction inlet of pump When installing...

Page 5: ...ectrical codes WARNING Electrical outlet must not be located in pump pit For best performance do not use electrical extension cords INSTALLATION DRAWING Lowest pump off level BE SURE TO MOUNT THE ION...

Page 6: ...the On level is at a point within the basin insuring that the Off level does not fall below the minimum level shown in the Installation Drawing ii If the On level is still too high the switch will ha...

Page 7: ...OPERATION MANUAL Dated 04 09 2018 Document Name WC33_OM Page 7 of 8 www ionproducts net Ion Digital Level Control Digital Level Control Switch Notes Notes...

Page 8: ...ect a defect in a product shall extend the Warranty beyond the period set forth above Metropolitan shall not be obligated to remedy any defect where otherwise required pursuant to the Warranty unless...

Reviews: