Manual log   

 

 

 

 

 

 

 

 

 

 

 

 
 

Manual Version 

Amendment 

Date updated  Instrument 

Firmware 

PC 
Software 
 

TVOC System 
Plus Manual 
V1.2 

Manual Reformatted 

10/02/2016 

V4.11 

N/A 

 

Summary of Contents for TVOC System Plus

Page 1: ...Part number 871026 Unrivalled Detection www ionscience com TVOC System Plus Instrument User Manual V1 2...

Page 2: ...TVOC SYSTEM PLUS MANUAL Ion Science Ltd Page 2 of 13 Unrivalled Detection www ionscience com...

Page 3: ...rical equipment for measurement control and laboratory use EMC Requirements Class B and General Immunity Other Standards BS EN ISO 9001 2000 Quality Management Systems Requirements BS EN 61010 1 2001...

Page 4: ...ility For Use 5 Getting Started 6 Packing List 6 Installation 7 Electrical Installation 7 15V power 7 Flow Fail Switch 7 TVOC System Overview 8 TVOC System Connections 9 DIN Rail Terminations 10 Servi...

Page 5: ...or similar sampling tubing is used so that any VOC s are not absorbed into the tubing walls The 4 20mA analogue output is wired directly from the TVOC instrument to a DIN rail mounted connector for ea...

Page 6: ...ystem Plus box should include Item Description Qty 1 TVOC instrument complete fitted 1 2 User manual TVOC Instrument 1 3 User manual System Plus Supplement 1 4 Mini Pump fitted 1 5 Water Trap Filter f...

Page 7: ...external 15V DC supply must be fused at 1A before entering the cabinet The supply is connected to the internal terminals see drawing below 15V power 15V positive terminal number 8 15V zero to termina...

Page 8: ...TVOC SYSTEM PLUS MANUAL Ion Science Ltd Page 8 of 13 Unrivalled Detection www ionscience com Installation TVOC System Overview...

Page 9: ...TVOC SYSTEM PLUS MANUAL Ion Science Ltd Page 9 of 13 Unrivalled Detection www ionscience com Installation TVOC System Connections...

Page 10: ...TVOC SYSTEM PLUS MANUAL Ion Science Ltd Page 10 of 13 Unrivalled Detection www ionscience com DIN Rail Terminations...

Page 11: ...mpled gas length of sample line being used etc etc As a guide we would recommend the following Service and Maintenance program Weekly Water Trap Filter check and remove any water in the unit To disass...

Page 12: ...mm OD 4mmID TUBE 06 Maintenance Flow Fail Switch The flow switch is factory pre set to fail at 200cc s This setting can be checked with a Multimeter using the SET terminal on the flow switch which sho...

Page 13: ...L Ion Science Ltd Page 13 of 13 Unrivalled Detection www ionscience com Manual log Manual Version Amendment Date updated Instrument Firmware PC Software TVOC System Plus Manual V1 2 Manual Reformatted...