29
Firmware Upgrade Succeeded
After the upgrade has completed, a screen appears to inform you that the procedure was
successful
Click
Finish
to close the Firmware Upgrade Utility
If the firmware upgrade fails, the Upgrade Succeeded screen will not appear.
Possible reasons for firmware upgrade failure are:
•
When a firmware upgrade was manually aborted
•
When the unit’s firmware becomes corrupted for some reason and unable
to be operated
•
When a firmware upgrade procedure is interrupted
To recover a failed firmware upgrade, do the following:
1. Power OFF the GCL1900W
2. Connect the Firmware Upgrade Cable to the Firmware Upgrade Port
3. Slide the Firmware Upgrade Switch to the Recover position
4. Power ON the GCL1900W and repeat the Firmware Upgrade Procedure
5. After the GCL1900W has been successfully upgraded, power the KVM console OFF,
and slide the Firmware Upgrade Switch back to the Normal position.
6. Then, power the GCL1900W back on again