14
MSK-101-MM | Installation instructions v1.7 OCT 2018 | msk-101-mm_instructions_en_us v1.7 | © 2017-2018 Inxpect SpA
4. Turn the base 180°.
5. Tighten the screws.
6. Extract the sensor from the adjustable
support.
7. Pass the cable into the sensor housing.
8. Assemble the sensor housing to the adapter.
Connect the sensor to the alarm
control unit
1. Remove the sheath and the hose by at least 5
cm (2 in).
2. Connect the power supply and relay outputs.
It is recommended to connect relay 3
(tampering) and 4 (fault) to a 24 h line from
the alarm control unit.
Installation and use