background image

These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible
contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please
contact your nearest representative.

Customer First Center  •  1121 Hwy 74 South  •  Peachtree City, GA  30269

IMI-574    AVU040082

Mesa

Sheet 2 of 3

3/10/04

IMI-574

INSTALLATION INSTRUCTIONS

IMPORTANT: 

Read carefully before installing fixture. Retain for future reference.

TM

WARNING: 

Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing
or servicing.

C. To wall mount a fixture with arm,
C1.

Using wall mount plate as a template, drill six (6) holes 
in wall. Install appropriate wall anchors (not supplied). 
Silicone caulk around junction box and wall anchors. 
Secure wall mount plate to wall with six (6) 
1/2-13 x 1-1/2 long bolts and six (6) lockwashers. 
Torque bolts to 450 in/lbs.

C2

. Extend supply wires from junction box to minimum 3 

feet in length.

C3

. Pull extended supply wires through arm and hook the 

arm over installed wall mount plate.

C4.

Secure the arm by tightening the set screw on bottom 
to approximately 215 in/lbs toward wall mount plate.

C5.

Repeat steps A1 through A9 above to mount fixture 
onto the arm.

D. To relamp,
D1. 

Loosen all four (4) captive screws at locations shown in Fig. D1 until 
disengaged inside.

D2

. On top of fixture, look for an arrow sign and word “OPEN HERE”. 

Open the top firmly and slowly from this location.

D3

. ENGAGE THE HINGE LOCK as shown in Fig. D2. Failure to engage the 

hinge may cause injury.

D4.

Rotate all four (4) U-shape brackets to unlock the reflector.

D5.

Remove the reflector.

D6.

Relamp. Make sure that the old lamp is cool before relamp.

D7.

Reposition the reflector.

D8.

Rotate all four (4) brackets to lock the reflector. Hand tighten each thumb 
screw on bracket if it is loose.

D9.

Hold the top firmly and DISENGAGE THE HINGE LOCK as shown in 
Fig. D2. Failure to disengage the hinge will cause hinge damage.

D10.

Close the top slowly.

D11.

Tighten back all four (4) captive screws.

1" SET SCREW

WALL

WALL ANCHORS

FIG. C

WALL MOUNT ARM

LOCKWASHERS

BOLTS

WALL MOUNT PLATE

J-BOX

SCREWS

BOTTOM VIEW

FIG. D1