Tools Required 

Allen Key (3/16”), Phillips screwdriver, electrical wiring tools.
1.  Remove the mounting plate from the fixture by 

loosening the two socket head cap screws using 3/16” 

allen key. (Figure 1.)

2.  Loosen the lock nut from the mounting plate.
3.  Detach tether from the mounting plate.
4.  Mount the mounting plate to the junction box or wall 

with gasket contacting wall, away from the luminaire 

and secure to the structure with screws (by others). 

Mounting plate must be in upright position as specified 

by label.

5.  Make sure plug at bottom of housing is in place 

properly as shown in Figure 1a.

6.  Make electrical connections.
7.  Re-attach tether to mounting plate.

8.  Tighten the lock nut.

ote: 

N

Tether must be able to rotate freely; therefore, do 

not over tighten lock nut. Fixture must hang from the 

tether, NOT from electrical wires.

9.  Slide the luminaire-mounting bracket over the top lid of 

the mounting plate to nest the hanging mechanism. 

Hold luminaire in place while allowing the back surface 

of luminaire to rest against wall.

10.  Screws must be captured behind lower beveled edge 

of mounting plate to ensure luminaire is secure. Press 

luminaire firmly against wall and re-tighten the two (2) 

socket head cap screws to secure the luminaire to the 

mounting plate. 

Thru-way Conduit / Battery Back Box 

1.  Remove the mounting plate from the back of thruway 

box by loosening two (2) Allen head screws. (Figure 2.)

2.  Mount the mounting plate to the wall using the four (4) 

larger holes with required hardware (by others). Plate 

must be in the correct upright position.

ote: 

N

Unit with a thruway box weighs more than 25 

pounds. Therefore, connect mounting plate to the 

wall using the 4 larger holes and appropriate anchors/

hardware (not provided).

3.  Slide the thruway box mounting bracket over the lid of 

the mounting plate.

4.  Re-tighten the two (2) Allen head screws to secure the 

thruway box to the mounting plate.

5.  If used with thru branch wiring, then remove plugs on 

side as required and install 3/4” NPS pipe. Seal pipe 

with Teflon tape or paste.

6.  Remove the thruway box cover from the thruway box 

housing by loosening five (5) screws. (Figure 2a.)

Figure 1.  

Figure  1a.  

Figure 2.  

Figure  2a.  

Fixture

Lock Nut

Tether

Gasket on 

Back

Allen Head Screw (2)

Door Latch

J-Box or Wall

Plug  

(Make sure this is in place 

before securing fixture to 

wall)

Thruway Box Cover

Thruway Box Housing

Mounting Plate 

Screws (x4)

Box cover 

screws (x5)

Mounting 

Plate

Thruway Box Cover

Allen Head 

Screws

Mounting Bracket

Mounting 

Plate

Mounting 

Screws

Allen Head Screws

Thruway Box Housing

Gasket

Mounting 

Bracket

Mounting Plate (Secure 

to J-Box or Wall)

Summary of Contents for Entri LED

Page 1: ...th the National Electrical Code and applicable local codes and ordinances Proper grounding is required to insure personal safety Carefully observe grounding procedure under installation section Notice This lighting fixture is designed for outdoor lighting services and should not be used in area of limited ventilation or inside high ambient temperature enclosures It must be stored in a dry location...

Page 2: ...naire firmly against wall and re tighten the two 2 socket head cap screws to secure the luminaire to the mounting plate Thru way Conduit Battery Back Box 1 Remove the mounting plate from the back of thruway box by loosening two 2 Allen head screws Figure 2 2 Mount the mounting plate to the wall using the four 4 larger holes with required hardware by others Plate must be in the correct upright posi...

Page 3: ... thruway box housing Figure 3 ote N Make sure wire plug stays in place 10 Attach the tether from the back of fixture to the mounting plate 11 Tighten the lock nut ote N Tether must be able to rotate freely therefore do not over tighten lock nut 12 Slide the luminaire mounting bracket over the top lid of the mounting plate 13 Tighten the two 2 Allen screws to secure the luminaire to the mounting pl...

Page 4: ...screws which secure the light square and trim ring to the fixture Figure 5 2 Place four spacers between vandal shield and trim ring 3 Align and secure vandal shield to luminaire with 4 provided screws Figure 5a Maintenance ote N A regular maintenance schedule should be followed to retain optimal light output and thermal performance Optical lens cleaning should be performed with a clean dry soft cl...

Page 5: ...u d une utilisation inappropriée imprudente ou négligente de ce produit AVIS Le fil de mise à la terre vert se trouve au bon endroit Ne le déplacez pas AVIS Prenez soin de ne pas déposer le luminaire sur les lentilles et de ne pas le soulever en posant vos mains sur les lentilles ote N Si le luminaire est commandé avec l option CBP Cold Weather Battery Pack ce luminaire est fourni avec un pack d é...

Page 6: ...nt la surface arrière du luminaire reposer contre le mur 10 Les vis doivent être capturées derrière le bord biseauté inférieur de la plaque de montage pour garantir la sécurité du luminaire Appuyez fermement le luminaire contre le mur et resserrez les deux 2 vis d assemblage à six pans creux pour fixer le luminaire à la plaque de montage Boite passe fil boite arrière de batterie 1 Retirez la plaqu...

Page 7: ... à tête hexagonale 8 Installez la plaque de montage du luminaire sur le couvercle de la boite passe fil à l aide des quatre 4 vis et des écrous fournis Figure 2 b 9 Tirez les fils d alimentation à travers le trou central et réinstallez le couvercle de la boite passe fil au logement de la boite passe fil Figure 3 ote N Assurez vous que la fiche du fil reste en place 10 Fixez le câble d attache de l...

Page 8: ... le luminaire carré et la garniture au luminaire Figure 5 2 Placez quatre entretoises entre le protecteur antivandalisme et la garniture 3 Alignez et fixez le protecteur antivandalisme au luminaire avec les quatre 4 vis fournies Figure 5a Entretien ote N Un horaire d entretien périodique doit être respecté pour maintenir un flux lumineux et une puissance thermique optimaux Le nettoyage des lentill...

Page 9: ...rra verde ya está ubicado correctamente No lo cambie de ubicación Aviso Se deben tomar precauciones para no bajar la luminaria sobre las lentes ópticas ni levantarla en el área de la lente ota N Si el dispositivo de iluminación se solicita con la opción CBP paquete de baterías para clima frío esta luminaria se proporciona con un paquete de iluminación de emergencia instalado de fábrica y debe ser ...

Page 10: ...naria se apoye contra la pared 10 Los tornillos se deben sujetar detrás del borde biselado inferior de la placa de montaje para garantizar que la luminaria esté firme Presione la luminaria firmemente contra la pared y vuelva a apretar los dos 2 tornillos de cabeza cilíndrica para sujetar la luminaria a la placa de montaje Conducto pasante caja posterior de la batería 1 Retire la placa de montaje d...

Page 11: ...nstale la placa de montaje de la luminaria en la cubierta de la caja pasante con cuatro 4 tornillos y tuercas provistos Figura 2b 9 Extraiga los cables de alimentación a través del orificio central y vuelva a instalar la cubierta en la carcasa de la caja pasante Figura 3 ota N Asegúrese de que el enchufe del cable permanezca en su lugar 10 Fije la correa desde la parte posterior de la luminaria a ...

Page 12: ...n el cubo de luz y el anillo de la moldura a la luminaria Figura 5 2 Coloque cuatro espaciadores entre la pantalla antivandalismo y el anillo de la moldura 3 Alinee y asegure la pantalla antivandalismo a la luminaria con 4 tornillos provistos Figura 5a Mantenimiento ota N Se debe seguir un cronograma de mantenimiento periódico para conservar la potencia de la luz y el rendimiento térmico óptimos L...

Page 13: ...es uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Declaración de la FCC Declaración de conformidad ...

Reviews: