IPE300 series engineering VFD
Basic operation guidelines
-78-
Function
code
Name
Description
Default
2: Input set through encoder, used
together with HDIA
HDIB lower limit frequency 0.000 kHz
0.000kHz
Corresponding setting of
HDIB lower limit frequency
-300.0%
–300.0%
0.0%
HDIB upper limit frequency
–50.000kHz
50.000kHz
Corresponding setting of
HDIB upper limit frequency
-300.0%
–300.0%
100.0%
HDIB frequency input filter
time
0.000s
–10.000s
0.030s
AI1 input signal type
0
–1
0: Voltage
1: Current
0
5.5.10 Analog output
The VFD carries one analog output terminal (0
–10V/0–20mA) and one high-speed pulse output
terminal. Analog output signals can be filtered separately, and the proportional relation can be
adjusted by setting the max. value, min. value, and the percentage of their corresponding output.
Analog output signal can output motor speed, output frequency, output current, motor torque and
motor power at a certain proportion.
0
1
2
3
.
.
.
.
.
.
19
20
P06.14
P06.16
AO1
HDO
P06.17
P06.18
P06.19
P06.20
P06.27
P06.28
P06.29
P06.30
P06.21
P06.31
(Default value is 0)
(Default value is 0)
P06.00
(HDO output type)
0
1
P06.00
0: Open collector high-speed
pulse output
1: Open-collector output
Analog output curve setting
Analog output selection
Analog output filter
Terminal output is described as follows:
Setting
Function
Description
0
Running frequency
0
–Max. output frequency