iMars series PV energy storage inverter
LCD operation instructions
43
6.4.3 Instruction for setup parameter
Name of
parameter
group
No
Menu
Name of setup
parameter
Instruction/Range of the set vaule
PV
parameter
1
Connect
mode
PV connect mode:
PV connection mode:
(0: Independent; 1:Parallel)
Inverter
parameter
1
Inverter
voltage
Inverter voltage
setup:
Inverter voltage setup (valid in off-grid
state), range: 208/220/230/240V
2
Inverter
frequency
Inverter frequency
setup:
Inverter frequency setup (valid in off-grid
state), range: 50/60Hz Hz
Grid
parameter
1
PF setup
PF setup:
PF value setup, range: -1.000~1.000
Battery
parameter
1
Battery type
Battery type:
Battery type:
0: Li-ion battery
1: Lead acid battery
2
Battery
protocol
Battery protocol
Battery protocol:
0: Reserved
1: PYLON
2:Sunwoda
3: YinLong
4:XingMei
3
Charge
voltage
Charge voltage
Charge voltage range:0~60V
4
Charge
current
Charge current
Charge current range:0~200A
5
Discharge
critical voltage
Discharge critical
voltage
Range:40~55V
Critical recovery
voltage
Range:40~55V(Recovery voltage must
be greater than the critical voltage)
6
Charge/Disch
arge enable
Charge enable
0: Disable; 1: Enable(Charging time
setting is effective after charging is
enabled)