ICA100-02 IoT Data Transmission Terminal
Operation guide
-8-
The first line is commands for setting up APN network, user name, and password.
The second line is commands for Modbus address clearing.
The third line is commands for setting up Modbus address of the device; M (device
quantity 1), W (5s waiting time), R (rewrite times), ADDR (address 1), B (baud rate), D
(data bit), S (stop bit), P (parity bit NONE:0,ODD:1
,
EVEN:2), T (J: construction
machinery), G: (number of register groups), group 1 (number of registers: start address of
register: data-rewrite interval), group 2 (number of registers: start address of register:
data-rewrite interval).
The forth line is commands for network port IP setting; MSIP (device IP), PORT (port),
LOCALIP (local IP).
The fifth line is commands for turning off the commissioning information.
The sixth line is commands for policy name which is the same as the file name.
The seventh line is the end line command.
Change the suffix of the file name to tac and click
Save
. Then, re-open the file path, and
click
Config
to complete. In the advanced function, click the corresponding policy inquiry
button and check in the feedback message box whether the policy is the same with the
setting.
2.
The
Advance
function allows you to view all configured policies and commissioning
information, set APN, and reset and upgrade the firmware version.
Note:
Policy file creation and burning can also be done in iWoStudio. See the iWoStudio
help manual for details.