BL4650
INSTRUCTION MANUAL
I Technical Specifications:
Item Code: BL4650
Name: SLIM LOCUS LIGHT
Voltage: AC 120V/230V, 60HZ/50Hz
Bulb: DWE 120V/max 650W(4X)
Protector: 125V/15A
(
2X
),
250V/10A
(
2X
)
Weight: 5.2kg
Size: L533x W454 x H112mm
II Operational Instructions:
1. Unpack the carton to check if there is any damaged or missing parts when
you receive the unit, call the local dealer if anything is found not in a normal
condition.
2. Open the lamp cover to install lamp . Keep the lamp untouched by hand and
disconnect the unit from power while Re-lamping.
3. Place the unit where there is efficient ventilation, away from any flammable
and explosive objects.
4. Check that the rated power corresponds to the main supply.
III Re-lamping:
1. Disconnect from power supply and cool down the unit before re-lamp .
2. Open the lid and replace the burnt-out lamp .
3. Restore the lid.
IV Caution:
1. In order to reach a maximum of safety the following points should be carefully
read and observed.
2. Ambient temperature should not exceed 40
℃.
3. Disconnect from the power supply before opening or replacement of the lamp.
Please be sure the lamp tube is cool before replacement!
4. To avoid electrical shock, do not touch any live parts when the unit is
activated.
5. Call professionals for maintenance, no spare parts are included with the unit.
6. The lamp shall be changed if it has become damaged or thermally deformed.
7. Please be sure to mount luminaires only as shown on the picture below, means
hanging on the bracket; Additionally, you can use a stable base for the fixing of
the luminaires.
8. Please ask an approved electrician because of special national requirements for
Electrical installation. No operation without proof by skilled electrician in
public area!
9. No naked flame sources, such as lighted candle, should be placed on the
apparatus,.
10. The use of apparatus should be in moderate climate.
11. The apparatus should not be exposed to dripping or splashing and that no
objects filled with liquids, such as vases, shall be placed on the apparatus.
12. Alternative precautions to switch off the device shall be taken if it is not easy
to reach the socket or switch off the lamp tube (e.g. additional disconnection
device).
V Installation: