3.2.6 Calibrating the Signal Field to the Loop Sensor
IMPORTANT:
Remember that the Loop Sensor must be located on the “loop side” of the lightning
protection device. The Loop Sensor should now be mounted on the wall. To calibrate the Loop
Sensor to the signal field, perform the following procedure.
1. RF Link Programming between the Loop Sensor and Dialer Unit must be successfully
completed before calibrating the Loop Sensor to the signal field. See section 3.1 for
additional information.
2. Double-check to make sure the signal field wires are securely placed in the wire channels on
the base of the Loop Sensor case.
3. Apply power to the Loop Sensor
a. The LED status indicator should show XXX.
i. This indicates power is on with no signal field present
4. Apply power to the transmitter
a. Adjust the signal to the appropriate signal field width.
b. The LED status indicator on the Loop Sensor should now show a XXXX indicating
detection of a signal field.
5.
Press and release the control button on the Loop Sensor [Show picture of Loop Sensor circuit
board with call-out]
.
The LED status indicator will be off during the signal field calibration.
6. Once calibration is complete, the LED status indicator will show a slow flashing green
indicating normal operating mode. This process should take no longer than fifteen seconds.
7. Replace the Loop Sensor cover.
3.3 Safe Dog Monitor Dialer Unit
3.3.1 Installation Diagram
Once the Dialer Unit has been successfully linked to the Loop Sensor, and the Loop Sensor has been
calibrated to the signal field, the Dialer Unit can be permanently installed near any working phone
jack. The phone jack should be within 250 feet of the Loop Sensor. An 110vAC outlet is also
required to provide power to the Dialer Unit. The Dialer Unit must be located within six feet of the
outlet due to the length of the power adapter cord.
[Show diagram of typical system installation]
3.3.2 Connecting Power
Power to the Dialer Unit will be supplied by a 10vDC wall adapter (included in the System Pack).
[Show picture of 10vDC adapter]
3.3.3 Connecting the Phone Line
Connect the Dialer to a working phone jack. There are two available phone jack connectors on the
Dialer Unit. Either connector can be used for connecting the Dialer Unit to the wall mounted phone