INVISIBLE FENCE Safe Dog Monitor Installation And Training Manual Download Page 4

- DRAFT - 

Rev. 1.0 JAB 

 

 

G:\PCTEST LAB\2006 Reports\TRP\Safe Dog Monitor - Part 68\TCB Documents\KZ3-050808 manual.doc 
Need Part Number 

 

1.0 Product Introduction 

 
This document contains important information regarding the installation and operation of the 
Invisible Fence

®

 Brand Safe Dog

®

 Monitor.  Prior installation of both the signal field wire and 

Invisible Fence Brand transmitter is assumed.  Review all instructions before installation and use. 
 

1.1 Safe Dog Monitor System Overview 

The Safe Dog Monitor is designed to continuously monitor the signal transmission of an Invisible 
Fence Brand transmitter and detect when a change occurs in signal amplitude – specifically, the 
detection of a wire break condition.  The Safe Dog Monitor will also detect an increase or decrease in 
the signal amplitude and an RF Link Communication failure between the Loop Sensor and Dialer 
Unit.  The Safe Dog Monitor is capable of monitoring the signal of the following Invisible Fence 
Brand transmitters: 

ICT 700 Series Transmitters (700, 725, 750, 775) 

ICT 800 Series Transmitters (801, 802, 810) 

Invisible Gate

®

 

Invisible Mask

®

 II 

 
Before the Safe Dog Monitor is installed, the Invisible Fence Brand pet containment system should 
be completely installed and operational. 
 

1.2 Important Precautions and Warnings 

Caution:

 Never install or service any Invisible Fence Brand equipment during a thunderstorm or 

electrical storm, or when thunder or lightning are in your area. 
 

1.3 Required System Components for Installation 

The following system components are required for installation of the Safe Dog Monitor. 

1.  Safe Dog Monitor Loop Sensor [Picture of Loop Sensor] 
2.  Safe Dog Monitor Dialer Unit [Picture of Dialer Unit] 
3.  Invisible Fence Brand 700 or 800 Series Transmitter, Invisible Gate, or Invisible Mask II 

[Picture of 725 and 801 transmitters] 

4.  Lightning Protection Device (for the Transmitters) – LP 4100/4200 or Max-Dog [Picture of 

4100 and Max Dog] 

5.  AC Adapter – For transmitter and Loop Sensor power supply [Picture of AC adapter] 
6.  Y-adapter for Loop Sensor power [Picture of Y-adapter] 
7.  DC Adapter for Dialer Unit power supply [Picture of Adapter] 
8.  Phone cable [Picture of phone cable included in system pack] 
9.  9-volt battery to for battery back-up on the Dialer Unit [Picture of 9-volt included in system 

pack] 

10. Optional: 12v Lead acid battery-back-up for transmitter and Loop Sensor 
11. Optional: Y-adapter for connecting Loop Sensor (Included in system pack, show picture) 

 
1.4 Product Specifications – Overview 

The Safe Dog Monitor consists of two main components: the Loop Sensor and the Dialer Unit.  The 
Loop Sensor is located in close proximity to the Invisible Fence Brand transmitter.  The Dialer Unit 
must be located near a working phone connection.  The Dialer Unit communicates with the Loop 

Summary of Contents for Safe Dog Monitor

Page 1: ...Rev 1 0 JAB Safe Dog Monitor Installation and Training Manual ...

Page 2: ...tallation Diagram 3 2 2 Mounting the Safe Dog Monitor Loop Sensor 3 2 3 Routing the Signal Field Wires 3 2 4 Connecting AC Power 3 2 5 Connecting to the Transmitter Battery Back up 3 2 6 Calibrating the Signal Field to the Loop Sensor 3 3 Safe Dog Monitor Dialer Unit 3 3 1 Installation Diagram 3 3 2 Connecting Power 3 3 3 Connecting the Phone Line 3 3 4 Successful RF Communication Link 3 3 5 Mount...

Page 3: ...EST LAB 2006 Reports TRP Safe Dog Monitor Part 68 TCB Documents KZ3 050808 manual doc Need Part Number 5 1 Registration Process 5 1 1 Pre registration 5 1 2 Registration Before Installation 5 1 3 Registration After Installation ...

Page 4: ...ings Caution Never install or service any Invisible Fence Brand equipment during a thunderstorm or electrical storm or when thunder or lightning are in your area 1 3 Required System Components for Installation The following system components are required for installation of the Safe Dog Monitor 1 Safe Dog Monitor Loop Sensor Picture of Loop Sensor 2 Safe Dog Monitor Dialer Unit Picture of Dialer U...

Page 5: ...ready linked to the Dialer Unit and the push button is pressed for less than two seconds the Loop Sensor will calibrate to the signal field These values will be used for determining the presence of a signal reduction increase loss imbalance 3 Pushing the button with for more than 10 seconds will reset the Loop Sensor to the default condition 1 6 Dialer Unit User Control The Dialer Unit has a push ...

Page 6: ...tor Pay careful attention to the sequence of the steps 3 1 Programming the Safe Dog Monitor Loop Sensor and Dialer Unit RF Link Programming of the Loop Sensor and Dialer Unit is critical to proper operation of the Safe Dog Monitor Without successful programming the Loop Sensor and Dialer Unit cannot communicate with each other The steps outlined in section 3 1 1 must be followed in order to succes...

Page 7: ...ate and remove it To fasten the Loop Sensor base to the wall you need two inch long 19mm 8 or 10 pan head sheet metal screws Show picture of Loop Sensor base pointing out mounting holes and wire channels with call outs 3 2 3 Routing the Signal Field Wires The next step in the installation process is to route the signal field wires coming from the LP 4100 through the wire channels in the Loop Senso...

Page 8: ...se the control button on the Loop Sensor Show picture of Loop Sensor circuit board with call out The LED status indicator will be off during the signal field calibration 6 Once calibration is complete the LED status indicator will show a slow flashing green indicating normal operating mode This process should take no longer than fifteen seconds 7 Replace the Loop Sensor cover 3 3 Safe Dog Monitor ...

Page 9: ...Dog Monitor Dialer Unit To mount the Dialer Unit to the wall first remove the cover of the unit To remove the cover hold the unit in one hand and using your thumb and index finger of your other hand gently compress the side of the cover plate and remove it To fasten the Dialer Unit base to the wall you need two inch long 19mm 8 or 10 pan head sheet metal screws Show picture of Dialer unit base poi...

Page 10: ...a loop low failure alarm when the signal field on either sensing circuit is reduced by X X of the calibration value The loop low failure notification will consist of a slow flashing Red LED and transmission of an alert to the Dialer Unit 4 2 2 Increase in Signal Field The Loop Sensor shall generate a loop high failure alarm when the signal field on either sensing circuit is increased by 50 150 of ...

Page 11: ...8 TCB Documents KZ3 050808 manual doc Need Part Number 5 Alert code The above information will only be transmitted to the Dealer and Distributor if the Safe Dog Monitor Registration process is completed Review section 5 0 for instructions on completing the registration process ...

Page 12: ...D is off System OK Green Slow 1 second on 4 seconds off Not linked to Dialer Unit Yellow Fast alternating on off RF Link Mode Red Green Alternating between red and green RF Link established not calibrated to the signal field Yellow Solid RF Link established no signal field detected Red Solid Fault condition detected Red Slow flash 1 second on 4 seconds off 4 5 2 Safe Dog Monitor Dialer Unit Condit...

Page 13: ...t level of registration If Invisible Fence Inc receives a notification call from a Dialer Unit that has only been through both this levels an email will be sent to the Distributor and Dealer The email alert notification will only contain the Dialer Unit serial number and the alert condition code Specific customer information will not be included For detailed directions on pre registering the Safe ...

Page 14: ...be done on the installation contract of installation checklist When the paperwork is returned to the office the information can be entered into the Safe Dog Monitor warranty database This site can be accessed at enter site address A user name and password is required to access this protected site A Safe Dog Monitor section is available to each Invisible Fence Brand Dealer This section allows the D...

Page 15: ... area An FCC compliant telephone cord and modular plug are provided with this equipment which is designed to connect to the telephone network or premises wiring using a Part 68 compliant compatible jack See installation instructions for details This equipment uses the following USOC jacks RJ11C If trouble is experienced with this equipment for repair or warranty information please contact your Inv...

Reviews: