Invicta Onsen Manual Download Page 2

   PAGE 3

INVICTA 

ONSEN INSTALLATION AND USER MANUAL

2. PRE-INSTALLATION

Congratulations on your purchase of the Onsen. This appliance should be installed and checked by a qualified 
professional. Ensure you have read the operation guidelines thoroughly prior to first use. For any questions or 
concerns please contact Oblica on 03 9416 0400. 
The installation process is outlined below:

– Determine position of firebox and flue carefully observing the clearances described within this section
– Install the external flue
– Install the internal flue and engage the firebox
– Ensure the floor has adequate protection

CAUTION:

Using components or parts other than those provided by the manufacturer or modifying the specification of 
components may result in inferior or unsafe operation. If such action is necessary, consult the manufacturer in the 
first instance. 

WARNING: 

• The appliance and flue-system must be installed in accordance with AS/NZS 2918 and the

relevant building code or codes.

• Any modification of the appliance that has not been approved in writing by the testing authority

will be in breach of the approval granted for compliance with AS/NZS 4013.

• Once the flue has been installed and approved by a professional installer, the flue must not be

modified in any way.

INVICTA 

ELTON INSTALLATION AND USER MANUAL

Summary of Contents for Onsen

Page 1: ...DATA WEIGHT AND DIMENSIONS Dimensions Firebox W500 x H1048 x D518mm Firebox weight 126kg Flue kit Standard 6 8 10 DETERMINED UNDER TEST CONDITIONS Nominal thermal output 6kW Efficiency Australian Test 61 Emissions Australian Test 0 6g kg 6 8 FLUE 500 1048 385 309 ...

Page 2: ... firebox Ensure the floor has adequate protection CAUTION Using components or parts other than those provided by the manufacturer or modifying the specification of components may result in inferior or unsafe operation If such action is necessary consult the manufacturer in the first instance WARNING The appliance and flue system must be installed in accordance with AS NZS 2918 and the relevant bui...

Page 3: ...ffice on 03 9416 0400 or email info oblica com au IMPORTANT Frames must also be considered Timber window frames must be treated as combustible surfaces see 2 3 Aluminium frames can be treated as non combustible surfaces see 2 2 2 PRE INSTALLATION CONTINUED 100 100 Non Combustible Non Combustible Glass frameless or aluminium frame Glass frameless or aluminium frame 350mm 350mm Combustible 550mm 115...

Page 4: ... thick and installed directly on combustible wall The sheet must be fixed with the 2000mm length fixed centrally behind the appliance and must extend to a height of 1200mm above the hearth 2 PRE INSTALLATION CONTINUED Combustible Combustible 2000mm 200mm 200mm Configuration 3 With Silicate board 30mm thick INVICTA ELTON INSTALLATION AND USER MANUAL ...

Page 5: ...USER MANUAL 3 INSTALLATION 3 1 Typical flue kit installation Cowl Chinaman Hat 8 Outer Case 10 Outer Case 8 Outer Case 10 Outer Case 6 Active Flue 6 Active Flue CEILING RING RUBBER DEKTITE FLASHING INVICTA ELTON INSTALLATION AND USER MANUAL ...

Page 6: ...ralian standards see diagrams below The top of the flue must be 400mm higher than the highest point of the roof Alternatively there must be a minimum distance of 3 meters from any higher section of roof 40 cm 40 cm 40 cm 8 m 120 cm 8 m 120 cm 120 cm 40 cm 40 cm 40 cm 8 m 120 cm 8 m 120 cm 120 cm The top of the flue must be 1200mm above the roofline Alternatively there must be a minimum distance of...

Page 7: ... material laid directly onto the concrete 200mm 300mm 200mm 825mm 705mm Joist Insulative board 8mm non combustible finish Non combustible finish eg tiles Concrete Combustible floor eg timber Joist Insulative board 8mm non combustible finish Combustible floor eg timber Combustible floor eg timber FLOOR PROTECTOR LAID ON TIMBER FLOOR 3 INSTALLATION CONTINUED 200mm 300mm 200mm 825mm 705mm Joist Insul...

Page 8: ...m Non combustible finish eg tiles Concrete Combustible floor eg timber 200mm 300mm Combustible floor eg Timber Floor protector 200mm 825mm 705mm Non combustible finish eg tiles Concrete Combustible floor eg timber FLOOR PROTECTOR LAID ON CONCRETE 3 INSTALLATION CONTINUED TOP VIEW INVICTA ELTON INSTALLATION AND USER MANUAL ...

Page 9: ...le the fire Do not use flammable liquids or aerosols in the vicinity of the fireplace when operating Do not store fuel within prescribed installation clearance distances The use of some types of preservative treated woods as a fuel can be hazardous IMPORTANT Misuse may lead to unhealthy and environmentally harmful emissions and will void any warranty or guarantee The maximum load capacity for the ...

Page 10: ... and Efficiency and AS NZS 4013 2014 for Flue Gas Emission using hardwood fuel ISSUE DATE 14 09 2018 INVESTIGATING OFFICER Steve Marland RESULTS The appliance particulate emission factor established in testing is 0 6g kg of dry wood within the maximum specification of 2 5g kg of dry wood and an average efficiency of 61 CONCLUSION This appliance does comply with the requirements of AS NZS 4013 2014...