Invicta 700GA Installation And User Manual Download Page 9

Insert 700GA 
insert 700 GA

 

Model: P967443

 

 

BP le 18/02/2020 

 

  Page 

9

 sur 

9

 

 

terre

neutre

phase

INSERT

bleu

rouge

INTERRUPTEUR

THERMIQUE

1

2

0

VENTILATEUR

VENTILATEUR

vert jaune

SCHEMA ELECTRIQUE

RESISTANCE

 

 

Summary of Contents for 700GA

Page 1: ...Insert 700GA insert 700 GA Model P967443 BP le 18 02 2020 Page 1 sur 9 Insert 700 Grand Angle R f rence P967443...

Page 2: ...ximale possible 60 cm D bit massique des fum es 8 5 g s Distance par rapport aux mat riaux combustibles adjacents Lat ralement 8cm dont 5 cm d isolant Au fond 13 cm dont 5cm d isolant caract ristique...

Page 3: ...d alimentation lectrique Pr voir sur l installation fixe un dispositif de s paration omnipolaire conform ment aux r gles d utilisation locales ce dispositif permettra d isoler l appareil du r seau d a...

Page 4: ...P967443 BP le 18 02 2020 Page 4 sur 9 4 6 8 10 11 12 14 15 16 17 18 19 20 22 21 23 24 26 29 31 32 33 35 36 38 39 40 42 43 45 46 61 47 48 52 53 64 55 56 57 58 62 31 31 7 13 28 63 9 30 1 2 3 5 25 27 34...

Page 5: ...e de 6 AV 4110060 27 1 Rondelle ventail de 6 AV 4150060 28 1 Axe de porte goupille cannel e 5x40 AV 6305400 29 1 Ecrou hexagonal de 5 AV 7100050 30 1 Ecrou hexagonal bas de 6 r glage fermeture AV 7100...

Page 6: ...n cessite un rechargement tout les d heures avec de petites quantit s de bois Il faut privil gier ce mode de fonctionnement particuli rement performant et respectueux de l environnement L appareil pe...

Page 7: ...fonctionnement satisfaisant Une fois cette adaptation effectu e ne plus agir sur ce registre d air secondaire et utiliser exclusivement le registre de r glage d allure pour faire varier la puissance d...

Page 8: ...t sur secteur 230V 50Hz Si le c ble d alimentation est endommag il doit tre remplac par le fabricant son SAV ou une personne de qualification similaire afin d viter un danger Celui ci doit tre remplac...

Page 9: ...Insert 700GA insert 700 GA Model P967443 BP le 18 02 2020 Page 9 sur 9 terre neutre phase INSERT bleu rouge INTERRUPTEUR THERMIQUE 1 2 0 VENTILATEUR VENTILATEUR vert jaune SCHEMA ELECTRIQUE RESISTANCE...

Page 10: ...Insert 700GA insert 700 GA Model P967443 BP le 18 02 2020 Page 1 sur 9 Woodstove insert 700 Wide angle Model P967443...

Page 11: ...stance from adjacent flammable material Horizontally 8cm 5 cm insulation Rear 13 cm 5cm insulation characteristics of the insulation 5cm layer of Rockwool maximum conductivity 0 04W m C with an alumin...

Page 12: ...to be connected to the electrical supply An omni polar separation device should be installed in accordance with local regulations This device will isolate the device from the electrical supply network...

Page 13: ...d Stove insert 700 GA model 967444 23 33 14 16 38 56 20 21 29 26 50 58 10 11 45 32 51 62 31 25 22 37 12 24 52 61 47 31 36 34 57 43 8 44 64 59 27 48 2 15 60 26 4 5 31 49 28 42 54 1 41 31 3 30 40 9 18 5...

Page 14: ...80 26 2 No 6 Washer AV 4110060 27 1 Tooth locking washer No 6 AV 4150060 28 1 Door hinge shaft grooved pin 5x40 AV 6305400 29 1 No 5 Hexagonal Nut AV 7100050 30 1 Lower closure adjustment nut 6 AV 710...

Page 15: ...ow heat initially to allow its components to dilate naturally Non continuous use or use of a long period 3 hours Non continuous use requires reloading small quantities of wood every 45 minutes We reco...

Page 16: ...above This setting can be changed to obtain a satisfactory output Once adjusted do not change the secondary airflow setting to modify the output of the stove Use the output regulator to increase or d...

Page 17: ...he cable and wall earth plugs are connected Connection to 230V 50 Hz mains power supply If the power cable is damaged it must be replaced by the manufacturer by after sales service or a similarly qual...

Page 18: ...BP on 11 02 2019 Page 9 10 Wood Stove insert 700 GA model 967444 Stove insert Neutral Positi ve 2 1 RESISTANC E 0 SWITCH THERMAL VENTILATOR VENTILATOR green yellow blue read WIRING DIAGRAM Earth...

Page 19: ...nstallation doit avoir Une alimentation en air frais d di la combustion Une vacuation des produits de combustion L appareil et l installation doivent tre entretenus r guli rement Toutes les surfaces d...