Wood Stove insert 700 GA 

         model 967444  

                     

 

 

 

Operation, connection and access to ventilators 119 x 119 x 38

 

 

Choice of ventilator mode:

 

 

 

POSITION 0: Not in operation or automatic mode

 

o

 

If you are not using your stove insert, the ventilators will not be in operation. 

o

 

When using the stove insert: 

 

The ventilators will start automatically when the temperature surrounding the stove 

increases. 

 

If the temperature drops, the ventilators will stop automatically (the time that the stove insert remains 

in operation is variable according to the intensity of the flame). 

 

POSITION 1: Low airflow / intensity of the flame, the ventilators reduce in speed. 

o

 

A light throughput of warm air ensures that the room continues to remain comfortably warm. 

 

POSITION 2: High airflow, maximum ventilator speed 

o

 

Maximum throughput of air which heats the room quickly. 

 

NOTE: Ventilators will not stop automatically in positions 1 and 2. Even when the fire is out, the ventilators continue to 
operate. 

 

Operations and information intended for qualified 

professionals

 

Connecting the power supply: 

 

 

The device is delivered with a temperature-resistant cable, appropriate for use in high-temperature areas. 

 

It is mandatory: 

o

 

To retain this type of cable in high-temperature areas. 

o

 

To connect to the power supply to ensure that the ventilators will operate, to cool the stove insert and avoid damage 

to electrical components. 

 

Connect the cable to the power supply ensuring that the cable and wall earth plugs are connected. Connection to 230V, 50 
Hz mains power supply 

 

If the power cable is damaged, it must be replaced by the manufacturer, by after-sales service or a similarly qualified person to 
avoid the risk of electrocution. The cable must have similar temperature-resistant characteristics and be installed by the 
manufacturer or after-sales service. 

 

The ventilators are visible through grills on each side of the ash pan. Take care in this area, avoid projections of water, do 
not introduce objects through the grills) 

 

Ventilator certified CSA-UD-VDE. Overall power consumption per ventilator: 19W Airflow rate: 160 m3/h per ventilator 

 

 

Access to ventilators: 

 

Ventilators can be accessed from inside the equipment. They are protected by 2 cast-iron covers. 

 

Proceed as follows 

o

 

Disconnect the electrical supply and ensure that it is not reconnected at any time during the maintenance operation. 

o

 

Remove the log guard which covers, at each end, a steel screw which retains the cover 

o

 

Remove the two screws using a number 5 Allen key 

o

 

Tap lightly with a hammer on the base of the cover to dislodge it 

o

 

Lift the cover and remove it from its housing 

o

 

Removed the left-hand ventilator by lifting it vertically 

o

 

To remove the right-hand ventilator (behind which is the electrical equipment) tilt it slightly towards the back of the 

stove insert and lift it 

o

 

Carefully disconnect both ventilators and the switch 

 

 

To reassemble 

o

 

Carefully follow the electrical assembly diagram 

o

 

Clean the covers and the base of each on which resistant glue which remain 

o

 

Apply the fire-resistant paste to the base and the covers to ensure airtightness. 

Summary of Contents for 700GA

Page 1: ...Insert 700GA insert 700 GA Model P967443 BP le 18 02 2020 Page 1 sur 9 Insert 700 Grand Angle R f rence P967443...

Page 2: ...ximale possible 60 cm D bit massique des fum es 8 5 g s Distance par rapport aux mat riaux combustibles adjacents Lat ralement 8cm dont 5 cm d isolant Au fond 13 cm dont 5cm d isolant caract ristique...

Page 3: ...d alimentation lectrique Pr voir sur l installation fixe un dispositif de s paration omnipolaire conform ment aux r gles d utilisation locales ce dispositif permettra d isoler l appareil du r seau d a...

Page 4: ...P967443 BP le 18 02 2020 Page 4 sur 9 4 6 8 10 11 12 14 15 16 17 18 19 20 22 21 23 24 26 29 31 32 33 35 36 38 39 40 42 43 45 46 61 47 48 52 53 64 55 56 57 58 62 31 31 7 13 28 63 9 30 1 2 3 5 25 27 34...

Page 5: ...e de 6 AV 4110060 27 1 Rondelle ventail de 6 AV 4150060 28 1 Axe de porte goupille cannel e 5x40 AV 6305400 29 1 Ecrou hexagonal de 5 AV 7100050 30 1 Ecrou hexagonal bas de 6 r glage fermeture AV 7100...

Page 6: ...n cessite un rechargement tout les d heures avec de petites quantit s de bois Il faut privil gier ce mode de fonctionnement particuli rement performant et respectueux de l environnement L appareil pe...

Page 7: ...fonctionnement satisfaisant Une fois cette adaptation effectu e ne plus agir sur ce registre d air secondaire et utiliser exclusivement le registre de r glage d allure pour faire varier la puissance d...

Page 8: ...t sur secteur 230V 50Hz Si le c ble d alimentation est endommag il doit tre remplac par le fabricant son SAV ou une personne de qualification similaire afin d viter un danger Celui ci doit tre remplac...

Page 9: ...Insert 700GA insert 700 GA Model P967443 BP le 18 02 2020 Page 9 sur 9 terre neutre phase INSERT bleu rouge INTERRUPTEUR THERMIQUE 1 2 0 VENTILATEUR VENTILATEUR vert jaune SCHEMA ELECTRIQUE RESISTANCE...

Page 10: ...Insert 700GA insert 700 GA Model P967443 BP le 18 02 2020 Page 1 sur 9 Woodstove insert 700 Wide angle Model P967443...

Page 11: ...stance from adjacent flammable material Horizontally 8cm 5 cm insulation Rear 13 cm 5cm insulation characteristics of the insulation 5cm layer of Rockwool maximum conductivity 0 04W m C with an alumin...

Page 12: ...to be connected to the electrical supply An omni polar separation device should be installed in accordance with local regulations This device will isolate the device from the electrical supply network...

Page 13: ...d Stove insert 700 GA model 967444 23 33 14 16 38 56 20 21 29 26 50 58 10 11 45 32 51 62 31 25 22 37 12 24 52 61 47 31 36 34 57 43 8 44 64 59 27 48 2 15 60 26 4 5 31 49 28 42 54 1 41 31 3 30 40 9 18 5...

Page 14: ...80 26 2 No 6 Washer AV 4110060 27 1 Tooth locking washer No 6 AV 4150060 28 1 Door hinge shaft grooved pin 5x40 AV 6305400 29 1 No 5 Hexagonal Nut AV 7100050 30 1 Lower closure adjustment nut 6 AV 710...

Page 15: ...ow heat initially to allow its components to dilate naturally Non continuous use or use of a long period 3 hours Non continuous use requires reloading small quantities of wood every 45 minutes We reco...

Page 16: ...above This setting can be changed to obtain a satisfactory output Once adjusted do not change the secondary airflow setting to modify the output of the stove Use the output regulator to increase or d...

Page 17: ...he cable and wall earth plugs are connected Connection to 230V 50 Hz mains power supply If the power cable is damaged it must be replaced by the manufacturer by after sales service or a similarly qual...

Page 18: ...BP on 11 02 2019 Page 9 10 Wood Stove insert 700 GA model 967444 Stove insert Neutral Positi ve 2 1 RESISTANC E 0 SWITCH THERMAL VENTILATOR VENTILATOR green yellow blue read WIRING DIAGRAM Earth...

Page 19: ...nstallation doit avoir Une alimentation en air frais d di la combustion Une vacuation des produits de combustion L appareil et l installation doivent tre entretenus r guli rement Toutes les surfaces d...