Page 1: ...INSTALLATION MANUAL Solar Water Heater ISP 2 0 Please read this installation manual carefully before using the appliance Keep this manual in a safe place...

Page 2: ...ion of the collector 17 2 How to mount the support for the collector 17 3 How to mount the collector 19 4 Sample drawing for the mounted collector 20 C Installation for vertical wall 21 1 When the col...

Page 3: ...Insulation thickness density sides 50kg m3 Insulation thickness sides mm 25 Absorber plate coating type TiNox Aperture area square metres 1 87 Absorber plate thickness mm 0 12 Absorber plate dimensio...

Page 4: ...of the inner surface of the riser pipe and header pipe When the liquid quantity and pipe diameter is fixed the pressure drop increases along with the increase of the roughness of the pipe s inner surf...

Page 5: ...4 CollectorDrowning and dimensions mm 3...

Page 6: ...area without icing weather can use water mix with slow release and anti bubbling agent as heat exchange medium but should notice the sediment problem The indirect system is not recommended to be used...

Page 7: ...e pipes which have been connected to make sure that the check valve gate valve filter and circulation pump are connected correctly and that the pipes and connectors have been tightened while the pipes...

Page 8: ...oozing It passes the test when there is no leakage or oozing and the pressure drop is less than 0 02MPa in 10 minutes Attention a The test pressure is 1 5 times of the pressure for opening the relief...

Page 9: ...it If liquid cannot be drained up from the system dry it by blowing the system with a blower don t stop blowing until the system is completely dry 4 Check the low temperature resistibility of the ant...

Page 10: ...d to the existing lightning belt with equipotential bonding The connection connection wire and anti corrosion method should follow the local regulation on the anti lightning system design 3 If the col...

Page 11: ...For different roof type T tile roof T color steel roof How to assemble the fittings of the collector How to connect and fix it with batten 1 Tile roof A Installation for sloped roof 9...

Page 12: ...F...

Page 13: ...ollector shall be mounted and fixed Step 2 Prepare angle iron pieces 5 L40 70 120 4 fix them onto the roof beam with wood screw 4 after drilling its side wall Step 3 Weld the bent collector connector...

Page 14: ...is a wrong mark in the drawing 4 Prepared bolt 5 Bolt 6 Nut Step 1 Build M12 bolt 4 onto roof with concrete If bolt 4 is not built in on the roof in advance the collector can be fixed with an expansi...

Page 15: ...ginal place when the collector connector is assembled Fix the channel steel with collector connector with bolt 5 mount the collector fixing hook 2 onto the lower channel steel cushion them with rubber...

Page 16: ...1 Collector 2 Collector fixing hook 3 Channel steel 4 Rubber pad J...

Page 17: ...2 Color steel roof K...

Page 18: ...tep 2 Insert the collector fixing bolt into the holes drilled assemble nut 7 and spring shim 6 in order and tighten them assemble nut2 gasket 3 and rubber gasket 4 in sequence with the collector fixin...

Page 19: ...on the outer frame of the collector 1 How to prefabricate the foundation of the collector Select a proper foundation for the collector according to the actual roof condition which may be a field casti...

Page 20: ...Step 3 Fix the channel steel 6 not the triangle frame assembled in step 2 with bolt 7 and nut 8 Step 4 Anti corrosion treatment When the support is finished treat it with hot galvanizing or paint it t...

Page 21: ...3 How to mount the collector 1 Collector 2 Collector fixing hook 3 Channel steel 4 Rubber pad O...

Page 22: ...ge of the collector with the collector fixing hook the upper edge of the collector shall be fixed through the fixing hole on its outer frame Connect the collector to the fixed channel steel with a bol...

Page 23: ...be mounted so as to prevent the disadvantages to the wall body such as deforming or cracks etc The light weight filled wall shall not be used as a structure to support the solar collector The support...

Page 24: ...1 When the collector is mounted to the external wall vertically R...

Page 25: ...holes Step 2 After drilling holes on the channel steel 2 fix the channel steel 2 and collector fixing hook 7 onto the external wall with expansion bolt 1 and nut 4 Step 3 Put the collector onto the c...

Page 26: ...2 When the collector is mounted to the external wall not vertically T...

Page 27: ...1 Support frame 2 Front support 3 Support connecting rod 4 Expansion bolt 5 Bolt 6 Collector 7 Bolt U...

Page 28: ...ighten and fix them Step 2 Drill holes on the external wall and insert expansion bolt 4 into the holes Step 3 Fix the support which has been assembled in step 1 onto the external wall Step 4 Put the c...

Page 29: ...Pipeline connection 1 Connection proposal for solar system with 1 panel W...

Page 30: ...e end is 22mm which connected with header pipe the other is stopped with G3 4 cap 2 collectors 1 2002 1025 80 mm 3 connector 2 One end is 22 which connected with header pipe the other is Male thread G...

Page 31: ...nough Y No Parts Qty Specification 1 Plug 2 One end is 22mmwhich connected with header pipe the other is stopped with G3 4 cap 2 collectors 2 2002 1025 80 mm 3 two way connector 2 Both ends for the he...

Page 32: ...tor array may be mounted in the following way For this kind of array of collectors 4 collectors shall be connected in parallel too and they are not put in one row The pipes and fittings shall be mount...

Page 33: ...r needs less mounting area but first two collectors shall be connected in parallel and then assemble two sets of the connected collectors in parallel too The pipes and fittings shall be mounted in the...

Page 34: ...ollectors in a serial or parallel way the above array way can be taken as an example When more than 4 collectors are going to be mounted on a row the serial mounting is not recommended i e the 3rd mou...

Page 35: ...temperature in the water tank with more than 10 C circulation will start automatically When temperature difference falls below 4 C circulation stops The whole process is automatic and no manual operat...

Page 36: ......