SYSTEM OVERVIEW: IV-LIGHT VENTILATION DEVICE
8
iV-Light ventilation device | Installation instructions
2
System overview: iV-Light ventilation device
The iV-Light ventilation device is designed to ventilate living rooms and bedrooms in single- and
multi-family houses, hotels and guest houses, rooms in public facilities and work rooms in office
buildings. It is suitable for installation in new buildings as well as for retrofitting in old buildings.
Installation is generally carried out in the exterior wall.
The ventilation device consists of a wall sleeve in which the thermal accumulator insert is mount-
ed. A lockable inner cover conceals the iV-Light discreetly from the interior. The filter integrated
into the inner cover ensures that no pollen or dust from outside enters the interior. Outside, a
weather protection hood conceals the components of the ventilation device.
The thermal accumulator insert includes a ceramic thermal accumulator and inVENTron, two
guiding vane elements and the Xenion reversible fan. The guiding vanes on both sides of the fan
serve to straighten the air flow and ensure more efficient flow through the thermal accumulator.
The unique geometry of the Xenion reversible fan effectively reduces sound transmission.
The standard length of the wall sleeve is 495 mm. For thicker walls, a wall sleeve with a length of
745 mm can be ordered. Both versions can be shortened on site.
The ventilation device is controlled via one of the following inVENTer system controllers
1)
:
• Pure
• sMove
• inVENTer Connect
2)
• MZ-Home
Components
•
Inner cover incl. ISO Coarse 60 % filter
• Thermal accumulator insert (thermal
accumulator and inVENTron)
• Wall sleeve
• External termination
•
Pollen and activated carbon filter
(optional)
• Sound and wind protection accessories
(optional)
Models
The ventilation devices of the iV-Light product range differ in their external terminations. Additional
inner covers are also available. This documentation only contains information on the standard
version of the ventilation device. For information on the variants of the external and internal
terminations, please refer to the separate installation instructions for the respective component.
• Standard variant:
iV-Light ventilation devices with weather protection grille (white).
1)
The operating instructions for the controller are not part of this documentation.
2)