Optidrive ODP-2ETHEG-IN User Guide Revisions 1.00
6
www.invertekdrives.com
2
Gener
al
In
fo
rm
ati
on
Network Status Indicator
State
Indication
Steady Off
Not powered, no IP address
Steady Green
Online, one or more connections active
Flashing Green
Online, no connections active
Flashing Red
Connection timeout
Steady Red
Duplicate IP
Flashing Green and Red
Self-test
Module Status Indicator
State
Indication
Steady Off
No power
Steady Green
Operating in normal condition
Flashing Green
Drive not configured
Flashing Red
Minor fault - Recoverable fault
Steady Red
Major fault - Unrecoverable fault
Flashing Green / Red
Self-test
COMM
State
Indication
Steady Off
Modbus protocol TX/RX inactive
Steady/flashing Yellow
Modbus protocol TX/RX active
ERROR
State
Indication
Steady Off
Modbus protocol TX/RX Status OK
Steady Red
Non-recoverable internal fault – Modbus communications circuit fault
Flashing Red
Recoverable Communication fault or configuration error
Link Activity LEDs (P1/P2)
State
Indication
P1 Speed
Steady Yellow
100Mbps link active
Steady Off
10Mbps or No link
P1 Link Activity
Steady Green
Valid Link
Steady Off
No Link
Flash
TX/RX
P2 Speed
Steady Yellow
100Mbps link active
Steady Off
10Mbps or No link
P2 Link Activity
Steady Green
Valid Link
Steady Off
No Link
Flash
TX/RX
2.5.
Power up sequence
At power up the following LED test sequence is performed in parallel:
Network Status Indicator – 0.25 sec RED, 0.25 sec Green
Module Status Indicator – 0.25 sec RED, 0.25 sec Green
COMM – 0.5 sec Yellow, 0.5 sec Off
ERROR – 0.5 sec Off, 0.5 sec RED
‘Running’ state