In the Time table you can set the language in which the time in the first line of the
display will be displayed:
6.6
Reactions to the events - I / O Settings
In the
Input 1
table, activating the
Door unlock
option allows the output relay (bolt) to
be automatically activated by activating Input 1.
In the
Output Relay
table can be set the operating mode of the bolt control relay.
O.n.
Name
Description
1
Mode
Disabled
- Turn off relay control.
1-Pulse
- After the activation of the output, the relay is switched on
for a certain time (eg the control of the bolt)
Toggle
- After activating the output, the state changes to the opposite
2
Time-on
Relay on time in
1-Pulse
mode, given in 0.1s (value 20 is 2 seconds)
3
Action
The action that causes the activation of the output.
None (control by protocol)
- The control is carried out through the
protocol HTTP, SMNP, MODBUS.
Every Card
- Activation of output with each RFID tag application.
Recogniza Card
- Activation of the output after applying the active
tag (stored in the reader's memory)
User manual RFID IND-U4, RFID IND-U2
Page
14
from
31