7

Charging

Many types of lead acid chargers are compatible with our PROTRXion™ batteries and safely 
charge in temperature ranges as shown in the table below. When choosing an intelligent char-
ger, please discuss with Inventus Technical Support on suitable off-the-shelf charger solutions. 
Charger datasheets can be provided upon request.

Recommended Charge Voltage / Current

Float Charge Voltage

Parallel connections 

The PROformance batteries can be connected in parallel to increase your energy requirements. 
You may connect up to 15 batteries for the M-24V80-TRX, M-24V90-TRX & M-36V80-TRX and 
up to 10 batteries for the M-48V60-TRX. These batteries cannot be connected in series. Refer to 
wiring diagram below.

Model

M-24V80-TRX

M-24V90-TRX

M-36V80-TRX

M-48V60-TRX

Charge Voltage

28.0 VDC

28.0 VDC

41.0 VDC

58.1 VDC

Charge Current

40A (0.5C)

45A (0.5C)

26.4A (0.33C)

18A (0.3C)

Charge Temperature

(with heater)

-35°C to 55°C 

(-31°F to 131°F)

-35°C to 45°C 

(-31°F to 113°F)

Charge Temperature

(without heater)

0°C to 55°C 

(32°F to 131°F)

0°C to 45°C 

(32°F to 113°F)

Model

M-24V80-TRX

M-24V90-TRX

M-36V80-TRX

M-48V60-TRX

Float Voltage

27.6 VDC

27.6 VDC

41.0 VDC

N/A

Single Install

Parallel Connection

Signal Cable

  

(System)

Pack (

-

)

Signal Cable

  

(System)

Pack (

+

)

Pack (

+

)

Pack (

-

)

Signal Cable

  

(Pack to Pack)

Summary of Contents for PROTRXion M-24V80-TRX

Page 1: ...er com info inventuspower com 1 877 423 4242 Inventus Power Inc 1200 Internationale Parkway Woodridge IL 60517 Designed Manufactured by PROTRXion Quick Start Guide M 24V80 TRX M 24V90 TRX M 36V80 TRX...

Page 2: ...hnical support team at Phone 1 877 423 4242 E mail tech_support inventuspower com Model Part No CANopen M 24V80 TRX with heater 58571 002 M 24V90 TRX with heater 57481 002 M 36V80 TRX with heater 5894...

Page 3: ...Mechanical Features 4 Torque Rating 5 Power Cables 5 Communication Cables 5 Pin Definition 6 Charging 7 Parallel connections 7 Wake Up Ship Mode 8 Installation 8 LED Status Operation Mode 9 Heater Op...

Page 4: ...If the product is being damaged during the installation process the standard warranty may be affected Mechanical Features If you have any questions please email tech_support inventuspower com Before i...

Page 5: ...o the battery signal connector and respective system or chargers See wiring diagram on page 7 Model Terminal Type Wrench Size Torque Nm M 24V80 TRX M 24V90 TRX M 36V80 TRX M 48V60 TRX ISO M8 x 1 25 x...

Page 6: ...ave internal termination resistance It is recommended to properly terminate the system and battery CAN Bus lines following the CAN Bus termination standards For any technical questions about properly...

Page 7: ...5 batteries for the M 24V80 TRX M 24V90 TRX M 36V80 TRX and up to 10 batteries for the M 48V60 TRX These batteries cannot be connected in series Refer to wiring diagram below Model M 24V80 TRX M 24V90...

Page 8: ...fcm or less torque in order to maintain good connection and avoid damaging the battery DO NOT rotate the mating connector or loosen the nut on the battery M12 connectors to avoid damaging the battery...

Page 9: ...rging If the ambient temperature reaches below 0 C 32 F the battery heater will activate to support charge mode until the battery pack temperature reaches above 5 C 41 F Charging will be prohibited wh...

Reviews: