background image

Installation and operation instructions 

VMS-47HB54 - RF-RH sensor  

1.  How to use this manual

 

This manual is intended as a reference book by which qualified 
installers can install the VMS-47HB54 

(henceforth called “device”) 

and users can use the device for its intended purpose. Make sure you 
have read and understood the manual before you install and/or use 
the device

 

1.2 

Intended use

  

The device is designed for following purposes

1.  To set the speed level of ventilation through the fan speed, based 

on user input or measured humidity level. 

2.  To set parameters for the ventilation control. 
Every other or further use is not in conformance with the intended 
use.

 

 

1.3 Working principle 

The device communicates with the ventilation system using wireless 
communications, in order to control the ventilation. Via the button and 
leds you can read and set the mode of control that the ventilation 
system currently is in. When in Auto mode, the device requests the 
level of ventilation based on the relative humidity (RH). 
 

1.3.1 Ventilation speeds and modes

 

The ventilation system runs in one of the following modes. 

Mode 

 

Fan Speed 

Away 

 

Low fan speed 

Home 

 

Medium fan speed 

Timer 

 

High fan speed, for a restricted 
duration 

Auto 

Auto  

Between Low fan speed and High fan 
speed, based on measured values 

The control device drives the fan based on the highest of values sent 
by the bound wireless sensor(s). 
When you start the timer mode from this device, the ventilation will be 
active for 30 minutes. 

 

1.3.2 RV meting 

The device continuously measures the relative humidity (RH) in the 
air. When in Auto mode, the device controls the ventilation based on 
the course of the measured values: the ventilation starts when the 
humidity gets above a certain level, or for some time when the 
humidity suddenly increases.

 

 

The device stores the configured fan speed values in the 
control device and requests them from there. 
The device stores the RH setpoint itself and does not 
communicate this with any other device

.  

 
 
 
 
 
 

1.4 Admonitions 

'Warning’

 identifies a hazard that could lead to personal 

injury, including death. 

 

’Note’

 is used to highlight additional information.

 

 

2. Content delivery 

  RF-Sensor (VMS-47HB54) 

 

 

1

 

  Battery 

 

 

1

 

  Mounting screws 

 

 

2

 

  Mounting plugs 

 

 

2

 

  Manual 

 

 

1

 

 

3. Safety  

The device meets the following EC directives

:

 

 

EMC directive: 

2014/30/EC

 

 

Low voltage directive:  

2014/35/EU

 

 

RTTE directive:  

2014/53/EU

 

 

RoHS directive:  

2011/65/EU

 

 

WEEE directive:  

2012/19/EU

 

 

4.  Signs on the device 

 

CE marking of conformity

.

  

 

Dispose according to European Community Directive 
2012/19/EU (WEEE)

).

 

 

General safety instructions 

The device is designed for indoor use only. Do not expose the 
device to rain or moisture, to avoid short circuit. Short circuit may 
cause fire or electric shock hazard. Operate the device between 
0°C and 40°C. For cleaning of the device use a soft damp cloth 
only. Never use any abrasive or chemical cleaner. Do not paint 
the device. 

 

5.Visual signals 

 

Status led   

 

Start up

 

 

White

 

Continuous

 

 

System status

 

 

Green

 

Continuous

 

Status OK

 

 

 
 

Red

 

1 flash

 

Com. Error

 

 

3 flashes

 

Fan error

 

 

4 flashes

 

RH sensor error

 

 

5 flashes

 

Low battery

 

Mode selection

 

 

 

Off

 

 

 

Mode leds

 

 

 

 

 

Auto

 

Start up

 

 

On

 

On

 

On

 

On

 

Mode selection

 

Away

 

*

 

 

 

 

Home

 

 

*

 

 

 

Timer

 

 

 

*

 

 

Auto

 

 

 

 

*

 

 

 

 

A: Status led 

B: Mode leds 

C: Touch button 

Reviews: