INVENTOR V7CRI-12WiFiR/U7RS-12 User Manual Download Page 30

30

Butoane si functii

Inainte de utilizarea noului aparat de aer conditionat, familiarizati-va cu telecomanda 

acestuia. In urmatoarele randuri regasiti o scurta prezentare. Pentru instructiuni legate 

de functionarea aparatului de aer conditionat, consultati rubrica “Cum se folosesc func

-

tiile de baza” din acest manual.

MODE 

Derulati prin modurile de operare 

dupa cum urmeaza 

AUTO 

 COOL 

 

DRY 

→ 

HEAT 

 

FAN

ECO/GEAR

Apasati acest buton pentru a intra in 

modul eficient de energie, dupa cum 

urmeaza: 

ECO 

 GEAR(75%)  

GEAR(50%) 

  Modul de setare anteri-

or 

→ 

ECO...

ΟΚ

Utilizat pentru a confirma functiile 

selectate.

TIMER

Seteaza temporizatorul pentru a porni 

sau opri unitatea.

PORNIT / OPRIT

Porneste sau opreste unitatea.

TEMP

Creste temperatura la inter-

val de 1°C (1°F).

Temperatura maxima este de 

30°C (86°F).

NOTA: Apasand concomitent 

butoanele   si   timp de 3 

secunde, temperatura de pe 

afisaj va alterna intre °C & °F.

SET

Derulati prin functiile de 

operare, dupa cum urmeaza:  

 Sleep (    ) 

Follow Me(   ) 

 AP mode ( ) ...

Simbolul selectat va clipi pe 

afisaj. Apasati butonul OK 

pentru a confirma.

BREEZE AWAY (nu este disponibil)

Aceasta caracteristica conduce fluxul 

direct de aer care sufla si va face sa va 

simtiti rasfatati.

NOTA:

 Aceasta caracteristica este 

disponibila numai in modul COOL, 

FAN si DRY.

TEMP 

Scade temperatura la interval 

de 1°C (1°F). Temperatura 

minima este de 16°C (60°F).

LED

Activeaza si dezactiveaza afisajul 

LED al unitatii interioare si buzzer-ul 

aparatului de aer conditionat (in func-

tie de model), care creeaza un mediu 

confortabil si linistit.

Turbo

Permite unitatii sa atinga temperatura 

presetata in cel mai scurt timp posibil.

FAN SPEED

Selecteaza viteza de ventilatie 

in urmatoarea succesiune:  

AU 

 20% 

 40% 

 60% 

 

80% 

 100%.

Apasand butonul TEMP   si 

 pentru a creste/micsora vi

-

teza ventilatorului la intervale 

de 1% .

SWING

Porneste si opreste miscarea 

orizontala a flapsului. Tineti 

apasat timp de 2 secunde 

pentru a initia functia de 

oscilare automata a flapsului 

vertical.

 

Before you begin using your new air conditioner, make sure to familiarize yourself with its remote 

control. The following is a brief introduction to the remote control itself. For instructions on how to 

operate your air conditioner, refer to the 

How to Use Basic Functions

 

section of this manual.

  

Buttons and Functions

04

ON/OFF 

SET

Turns the unit on or off.

MODE

OK

TIMER

BREEZE AWAY - not available

LED

Turbo

ECO/GEAR

Scrolls through operation modes 

as follows:  

AUTO

 

 

COOL

 

 

DRY

 

HEAT

 

 

FAN

FAN SPEED

SWING

Increases temperate in 

1°C (1°F) increments. 

Max. temperature is 

30°C (86°F).

NOTE: Press together     &

     buttons at the same time

for 3 seconds will alternate

the temperature display

between the °C &  °F.

TEMP

TEMP

Used to confirm the selected 

functions

 

 

 

Decreases temperature 

O

O

in 1 C(1 F) increments. 

Min. temperature is 

O

O

16 C(60 F). 

Starts and stops the horizontal 

louver movement. 

This feature avoids direct air flow

 blowing on the body and makes 

 you feel indulging in silky coolness.

NOTE:

 This feature is available

under cool, Fan and Dry mode only

   Set timer to turn unit on or off

  ECO     GEAR(75%)

      GEAR(50%)    

mode     ECO

......

Scrolls through operation

functions as follows:

The selected symbol will 

flash on the display area, 

press the OK button to 

confirm.

   Selects fan speeds in the

   following order:  AU 

 20% 

60% 

 40% 

 80%   100%. 

Press the TEMP    or     button

to increase/decrease the fan

speed in 1% increments. 

Enables unit to reach preset

temperature in shortest possible

time. 

Previous setting

 

 

Turns indoor unit’s LED  display 

and air conditioner buzzer on and 

off (model dependent), which 

create a comfortable and quiet

environment.  

  Press this button to enter the

  energy efficient mode in a  

  sequence of following:    

Vane

Vane

Press to enter the louver setting

mode.

Sleep(    ) Follow Me(     )   

AP mode (    )    Active

clean(     ) ......

Active clean(      ) 

  

Model: RG10N2(D2S)

CLEAN

Folosit pentru a porni / opri functia 

Auto Clean sau Active Clean. (Depin

-

de de model, va rugam sa consultati 

MANUALUL DE FUNCTIONARE SI 

INSTALARE AL UTILIZATORULUI).

Model: 

RG10A(D2S)

Clean

Summary of Contents for V7CRI-12WiFiR/U7RS-12

Page 1: ...SYSTEMS MODELS V7DI 12WiFiR U7RS 12 V7DI 18WiFiR U7RS 18 V7DI 24WiFiR U7RS 24 V7DI 36WiFiR U7RS 36 V7DI 42WiFiR U7RS 42 V7DI 50WiFiR U7RT 50 V7DI 60WiFiR U7RT 60 V7CRI 12WiFiR U7RS 12 V7CRI 18WiFiR U...

Page 2: ......

Page 3: ...ontents Remote Controller Specifications 02 Handling the Remote Controller 03 Buttons and Functions 04 Remote Screen Indicators 08 How to Use Basic Functions 09 How to Use Advanced Functions 11 04 05...

Page 4: ...rol will have no effect When there are wide differentces between Remote controller Manual and USER S MANUAL on function description the description of USER S MANUAL shall prevail Remote Controller Spe...

Page 5: ...of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference th...

Page 6: ...horizontal louver movement Hold down for 2 seconds to initiate vertical louver auto swing feature This feature avoids direct air flow blowing on the body and makes you feel indulging in silky coolnes...

Page 7: ...rature Timer Fan speed display Active clean feature display Fresh feature display not available Sleep mode display Follow me feature display Wireless control feature display Low battery detection disp...

Page 8: ...e Set your desired temperature Turn on the air conditioner FAN Mode Select FAN mode Turn on the air conditioner Select COOL HEAT mode Set the temperature Turn on the air conditioner Set the fan speed...

Page 9: ...r 24 2 Cancel either function by setting its timer to 0 0h Point remote to unit and wait 1sec the TIMER ON will be activated Press TIMER button to initiate the OFF time sequence Point remote to unit a...

Page 10: ...swing up and down automatically when pressing Swing button Press again to make it stop Keep pressing this button more than 2 seconds the vertical louver swing function is activated Model dependent 2s...

Page 11: ...CO operation the set tmeperature should be 24 C 75 F or above it may result in insufficient cooling If you feel uncomfortable just press the ECO button again to stop it O O O O O O O O O O Press X ECO...

Page 12: ...lean 5s 5s Turbo Press this button 2 times during one second under HEAT Mode and setting temperature of 16 C 60 F or 20 C 68 F The unit will operate at high fan speed while compressor on with temperat...

Page 13: ...signal to the air conditioner every 3 minutes interval When using AUTO COOL or HEAT modes measuring ambient temperature from the remote control instead of from the indoor unit itself will enable the a...

Page 14: ...ign and the specifications of the product for reasons such as product improvement are subject to change without any prior notice Please consult with the manufacturer at 30 211 300 3300 or with the Sal...

Page 15: ...15 16 17 18 LCD 19 20 22...

Page 16: ...O ff Fan Slee p AUT O COO L DRY HEA T FAN HIG H MED LOW SET TEMPERA TURE 5 RG10A D2S 3 0V R03 LR03 2 8m 5 C 60 C 23 F 140 F ON OFF NOT SURE WHAT A FUNCTION DOES Refer to the How to Use Basic Function...

Page 17: ...subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operat...

Page 18: ...indulging in silky coolness NOTE This feature is available under cool Fan and Dry mode only Set timer to turn unit on or off ECO GEAR 75 GEAR 50 mode ECO Scrolls through operation functions as follow...

Page 19: ...Not available for this unit Temperature Timer Fan speed display Active clean feature display Fresh feature display not available Sleep mode display Follow me feature display Wireless control feature d...

Page 20: ...peration please ensure the unit is plugged in and power is available ATTENTION MODE MODE MODE COOL HEAT COOL HEAT DRY MODE How to Use Basic Functions AUTO Mode COOL or HEAT Mode DRY Mode Select AUTO m...

Page 21: ...M ER ON TIM ER OFF TEM P SLE EP ON OFF MO DE FA N SH OR T CU T TIM ER ON TIM ER OFF TE MP SLE EP 1sec x5 xn xn x10 xn Keep in mind that the time periods you set for both functions refer to hours after...

Page 22: ...ver will swing up and down automatically when pressing Swing button Press again to make it stop Keep pressing this button more than 2 seconds the vertical louver swing function is activated Model depe...

Page 23: ...ting the set temperature to less than 24 C 75 F will stop ECO operation Under ECO operation the set tmeperature should be 24 C 75 F or above it may result in insufficient cooling If you feel uncomfort...

Page 24: ...ean button while operating will cancel silence function Silence function Clean 5s 5s Turbo Press this button 2 times during one second under HEAT Mode and setting temperature of 16 C 60 F or 20 C 68 F...

Page 25: ...Sleep Follow Me AP mode Active clean Active clean function The Active Clean Technology washes away dust mold and grease that may cause odors when it adheres to the heat exchanger by automatically fre...

Page 26: ...26 211 300 3300 www inventoraircondition gr media library...

Page 27: ...27 Specificatiile telecomenzii 28 Utilizarea telecomenzii 29 Butoane si functii 30 Indicatori ecran 31 Cum se folosesc functiile de baza 32 Cum se folosesc functiile avansate 34 CUPRINS...

Page 28: ...ilizeaza functiile de baza si Cum se utilizeaza functiile avansate din acest manual pentru o descriere detaliata a modului de utilizare a aparatului de aer conditionat NOTA SPECIALA Modelele butoanelo...

Page 29: ...erate the equipment 03 Handling the Remote Controller Folosirea telecomenzii INTRODUCEREA SI INLOCUIREA BATERIILOR OBSERVATII PENTRU UTILIZAREA TELECOMENZII SFATURI PENTRU UTILIZAREA TELE COMENZII Dis...

Page 30: ...2 secunde pentru a initia functia de oscilare automata a flapsului vertical Before you begin using your new air conditioner make sure to familiarize yourself with its remote control The following is a...

Page 31: ...en Indicators Note All indicators shown in the figure are for the purpose of clear presentation But during the actual operation only the relative function signs are shown on the display window Note No...

Page 32: ...and power is available ATTENTION MODE MODE MODE Mod COOL sau HEAT Selectati COOL HEAT Alegeti temperatura Setativitezaventilatorului Pornitiaparatulde aerconditionat Mod DRY MODE How to Use Basic Func...

Page 33: ...ER ON sau TIMER OFF timpul va creste in trepte de 30 de minute cu fiecare apasare pana la 10 ore Pentru 10 ore si pana la 24 va creste in trepte de 1 ora De exemplu apasa ti de 5 ori pentru a obtine 2...

Page 34: ...apasati acest buton mai mult de 2 secunde functia de oscilatie verticala a flapsurilor este activa in functie de model How to Use Advanced Functions Swing function LED DISPLAY Press Swing button The h...

Page 35: ...GEAR afisajul de pe telecomanda va alterna intre consumul de energie electrica si temperatura setata ECO GEAR function Under cooling mode press this button the remote controller will adjust the temper...

Page 36: ...nd Temp button while operating will cancel this function Functia Silent Continuati sa apasati butonul FAN mai mult de 2 secunde pentru a activa dezactiva functia Silent unele unitati Datorita function...

Page 37: ...e memory feature is stopped OF displays for 3 seconds on the screen While the memory feature is activated press the ON OFF button shift the mode or power failure will not cancel the Follow me function...

Page 38: ...pot schimba fara o notificare prealabila datorita imbunatatirii continue a echipamentelor noastre Pentru mai multe detalii va rugam sa contactati producatorul la numarul de telefon 30 211 300 3300 sau...

Page 39: ...erzeichnis Spezifikationen der Fernbedienung 40 Bedienung der Fernbedienung 41 Tasten und Funktionen 42 Entfernte Bildschirmanzeigen 43 Verwendung der Grundfunktionen 44 Verwendung der erweiterten Fun...

Page 40: ...imaanlage finden Sie in den Abschnitten Grundfunktionen und Erweiterte Funktionen dieses Handbuchs f r eine detaillierte Beschreibung wie Sie Ihre Klimaanlage verwenden BESONDERER HINWEIS Das Design d...

Page 41: ...seln der Bat terien HINWEISE ZUR VERWENDUNG DER FERNBEDIENUNG TIPPS ZUR VERWENDUNG DER FERNBE DIENUNG HINWEISE ZUR VERWENDUNG DER FERNBEDIENUNG Das Ger t k nnte den rtlichen nationalen Vorschriften en...

Page 42: ...r die Bedienung des Klimager tes finden Sie im Abschnitt Grundlegende Funktionen in dieser Anleitung MODUS Wechselt durch die Betriebsarten wie folgt AUTOMATISCH K HLEN TROCKEN HEIZEN FTEN HINWEIS De...

Page 43: ...ode display Follow me feature display Wireless control feature display Low battery detection display flashing Displays when LOCK feature is activated Silence LOW MED HIGH AUTO Lights up when remote se...

Page 44: ...dus K HLEN oder HEIZEN Betriebsart K HLEN HEI ZEN w hlen Stellen Sie die Tempera tur ein EinstellenderVentilator geschwindigkeit SchaltenSiedas Klimager tein Betriebsart DRY Modus MODE How to Use Basi...

Page 45: ...p to 24 it will increase in 1 hour increments For example press 5 times to get 2 5h and press 10 times to get 5h The timer will revert to 0 0 after 24 2 Cancel either function by setting its timer to...

Page 46: ...ab automa tisch wenn Sie die Taste Swing dr cken Dr cken Sie erneut um sie zu stoppen LED ANZEIGE LED Taste dr cken Dr cken Sie diese Taste zum Ein und Ausschalten des Anzeigefeldes am Innenger t Halt...

Page 47: ...ktrischer Energieverbrauch Vorheriger Einstellmodus Im Stuffen GEAR Betrieb wechselt die Anzeige auf der Fernbedienung zwischen elek trischer Energieverbrauch und eingestellte Temperatur ECO GEAR func...

Page 48: ...Funktion Halten Sie die L ftertaste l nger als 2 Sekunden gedr ckt um die Silence Stille Funktion zu aktivieren deaktivieren einige Ger te Aufgrund des Niederfrequenzbetriebs des Kompressors kann es z...

Page 49: ...ry feature is activated On displays for 3 seconds on the screen SET Funktion Dr cken Sie die SET Taste um die Funktionseinstellung aufzurufen dr cken Sie dann die SET Taste oder die TEMP Taste um die...

Page 50: ...dieses Handbuchs und die technischen Daten dieses Produkts k nnen f r Verbesserungsgr nde ohne Vorank ndigung ge ndert werden Bitte wenden Sie sich an den Hersteller unter 30 211 300 3300 oder an die...

Page 51: ......

Page 52: ...E CONTROLLER AIR CONDITIONING SYSTEMS Manufacturer INVENTOR A G S A 24th km National Road Athens Lamia 2 Thoukididou Str Ag Stefanos 14565 Tel 30 211 300 3300 Fax 30 211 300 3333 www inventor ac V 1 0...

Reviews: