Troubleshooting 8
4. Information Inquiry
• To enter information inquiry status, complete the following procedure within 10 seconds:
• Press LED 3 times.
• Press SWING 3 times.
• Finish 1 and 2 within 10 seconds, you will hear beeps for two seconds, which means the unit goes into parameter
checking mode.
• Use the LED(or DO NOT DISTURB) and SWING(or AIR DIRECTION) buttons to cycle through information displayed.
• Pressing LED(or DO NOT DISTURB) displays the next code in the sequence. Pressing SWING(or AIR DIRECTION) will
show the previous.
• The following table shows information codes. The screen displays this code for 1.2 seconds, then the information for
25 seconds.
Displayed code
Explanation
Additional Notes
Error code
Refer to next list of error code
T1
T1
T1 temperature
T2
T2
T2 temperature
T3
T3
T3 temperature
T4
T4
T4 temperature
TP
TP
TP temperature
Targeted frequency
FT
Targeted Frequency
Actual frequency
f
r
Actual Frequency
Compressor current
L
N/A
Outdoor AC voltage
U
N/A
Indoor capacity test
S
n
N/A
Reserve
--
N/A
Outdoor fan speed
P
r
Outdoor fan speed=value*8
EXV opening angle
L
r
EXV opening angle-value*8
Indoor fan speed
I
r
Indoor fan speed=value*8
Indoor humidity
HU
N/A
Adjusted setting temperature
TT
N/A
Reserve
--
N/A
Reserve
--
N/A
Reserve
--
N/A
GA algorithm frequency
T
N/A
Summary of Contents for U6MRS32-18
Page 1: ...SERVICE MANUAL ENGLISH AIR CONDITIONING SYSTEMS LCAC...
Page 4: ......
Page 5: ...Contents 1 Precautions 2 2 Information servicing For flammable materials 3 Safety Precautions...
Page 11: ...Contents 1 Model Reference 2 2 External Appearance 3 Model Reference...
Page 14: ...Model Reference 4 2 2 Outdoor Unit Outdoor Unit...
Page 18: ...IDU Compact Cassette 4 2 Dimensional Drawings...
Page 20: ...IDU Compact Cassette 6 4 Service Place...
Page 49: ...IDU A6 Duct 8 6 Fan Performance 18K...
Page 50: ...IDU A6 Duct 9 Constant air volume...
Page 68: ...IDU Floor Ceiling 5 4 Service Place 35mm 1 38in 1m 3 28ft 35mm 1 38in 35mm 1 38ch...
Page 93: ...Outdoor Unit 3 Panel Plate B30...
Page 94: ...Outdoor Unit 4 Panel Plate BA30...
Page 95: ...Outdoor Unit 5 Panel Plate CA30...
Page 96: ...Outdoor Unit 6 Panel Plate D30...
Page 97: ...Outdoor Unit 7 Panel Plate E30...
Page 98: ...Outdoor Unit 8 Panel Plate 590...
Page 99: ...Outdoor Unit 9 2 Service Place...
Page 110: ...Wiring Diagrams Outdoor unit wiring diagram 16022000022493...
Page 111: ...Outdoor unit printed circuit board diagram 17122000002718...
Page 280: ...AIR CONDITIONING SYSTEMS LCAC Scan here to download the latest version of this manual...