![INVENTOR S2VI-09 Owner'S Manual Download Page 36](http://html1.mh-extra.com/html/inventor/s2vi-09/s2vi-09_owners-manual_2084114036.webp)
31
Φ6 - 6.35(1/4")
Φ9.52(3/8")
Φ12-12.7(1/2")
Φ15.8-16(5/8")
1.3
0.7
1.6
1.0
1.8
1.0
2.4
2.2
Pipe expanding method
Note:
Improper pipe expanding is the main cause of refrigerant leakage. Please expand
the pipe according to the following steps:
A: Cut the pipe
● Confirm the pipe length according to
the distance of indoor unit and
outdoor unit.
● Cut the required pipe with pipe cutter.
pipe
pipe cutter
leaning
uneven
burr
B: Remove the burrs
● Remove the burrs with shaper and
prevent the burrs from getting into
the pipe.
downwards
pipe
shaper
C: Put on suitable insulating pipe
D: Put on the union nut
● Remove the union nut on the indoor
connection pipe and outdoor valve;
install the union nut on the pipe.
union pipe
pipe
E: Expand the port
● Expand the port with expander.
Note:
● "A" is different according to the
diameter, please refer to the sheet
below:
expander
hard
mold
pipe
F: Inspection
● Check the quality of expanding port.
If there is any blemish, expand the
port again according to the steps
above.
the length is equal
improper expanding
leaning
damaged
surface
crack
uneven
thickness
smooth surface
Outer diameter
(mm)
A(mm)
Max
Min
Summary of Contents for S2VI-09
Page 2: ...S2VI 09 S2VO 09 S2VI 12 S2VO 12...
Page 37: ......
Page 38: ...1 6 8 8 9 11 12 12 13 13 16 20 21 21 22 23 28 31 28 29 R410A R32 125 50 50 2087 5...
Page 39: ...1 8 adaptor...
Page 40: ...2...
Page 41: ...3 3...
Page 42: ...4 NEC CEC...
Page 43: ...5 32 23 43 26 27 24 18 DB WB C DB WB C 15 C 43 C 15 C 24 C 20 C 24 C...
Page 44: ...6 Display content or position may be di aux button...
Page 45: ...W R G W R O G W R LED LED W R O LED LED 7...
Page 48: ...9 F 5 6 7 OFF CLOCK 8 TIMER ON 2 1 0 5 10 0 5 1 2 TIMER ON TIMER ON...
Page 51: ...12 1 ON OFF 2 MODE 3 4 FAN 5 1 Sleep 2 TIMER ON TIMER OFF 3 LIGHT 4 Turbo...
Page 52: ...13 1 2 7 1 5V 3 8...
Page 53: ...13 AUX aux...
Page 54: ...14 1 2 3 4 3 45 C...
Page 55: ...15 1 2 3 4 service 5 service 1 2 1 2...
Page 57: ...17 3 AUTO MODE AUTO 16 C 30o C...
Page 58: ...18...
Page 59: ...19 E5 E8 U8 H6 C5 F1 F2...
Page 60: ...20 250cm 15cm 300cm 15cm 15cm...
Page 61: ...21 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 2 3 4 5 6 2 5 7 8...
Page 62: ...22 1 2 3 4 5 6 7 8 9 1 2 3 4 5 3...
Page 63: ...23 55mm 55mm QD 55mm 55mm QB 1 2 3 ST4 2X25TA 1 2 55 70 5 10 150mm 150mm 150mm 150mm...
Page 64: ...24 5 10 55 1 1 2 3 2...
Page 65: ...25 2 1 m 6 9 52 12 16 19 30 40 45 55 60 65 70 75 15 20 4 1...
Page 66: ...26 N 1 2 3 2 2 3 o y 3mm 4 5...
Page 67: ...27 r 1 2 1 2 3 4 5 3 4...
Page 68: ...28 1 2 ON OFF MODE AUTO COOL DRY FAN HEAT...
Page 73: ......
Page 108: ......