Introduction for buttons on remote controller
X-FAN button
9
Pressing X-FAN button in COOL or DRY mode, the icon is displayed and the
TEMP button
10
Press this button, could select displaying the indoor setting temperature or indoor
TIMER OFF button
11
Once press this key to enter into TIMER OFF setup, in which case the TIMER OFF
TURBO button
12
In Cool or Heat mode, press this button can turn on or turn off the Turbo function.
SLEEP button
13
Press this button, Sleep On and Sleep Off can be selected. After powered on, Sleep
Off is defaulted. After the unit is turned off, the Sleep function is canceled. After Sleep
function set up, the signal of Sleep will display.In this mode,
the time of timer can be
adjusted. Under Fan and Auto modes, this function is not available.
After turned on the Turbo function, its signal will be displayed. When switching the
mode or changing fan speed, this function will be canceled automatically.
icon will blink.
The method of setting is the same as for TIMER ON.
ambient temperature. When the indoor unit firstly power on it will display the setting
temperature, if the temperature's displaying status is changed from other status to
control signal that will return to display the setting temperature. if the users haven't
set up the temperature displaying status, that will display the setting temperature.
(This function is applicable to partial of models)
After powered on, the setting temperature displaying is defaulted, (according to cust-
omers requirements to display, if there is no requirement that will default to display
Press this button, (When displaying ), will display presetting temperature; (when
displaying ) will display indoor ambient temperature, current displaying status
will not be changed. If current displays indoor ambient temperature, if received the
other remote control signal, it will display presetting temperature, 5s later, will back
to display the ambient temperature.
(This function is applicable to partial ofmodels)
the presetting temperature and there is no icon displayed on wireless remote control).
" ", displays the ambient temperature, 5s later or within 5s, it receives other remote
indoor fan will continue operation for 10 minutes in order to dry the indoor unit even
though you have turned off the unit. After energization, X-FAN OFF is defaulted.
X-FAN is not available in AUTO, FAN or HEAT mode.
Summary of Contents for S2VI-09
Page 2: ...S2VI 09 S2VO 09 S2VI 12 S2VO 12...
Page 37: ......
Page 38: ...1 6 8 8 9 11 12 12 13 13 16 20 21 21 22 23 28 31 28 29 R410A R32 125 50 50 2087 5...
Page 39: ...1 8 adaptor...
Page 40: ...2...
Page 41: ...3 3...
Page 42: ...4 NEC CEC...
Page 43: ...5 32 23 43 26 27 24 18 DB WB C DB WB C 15 C 43 C 15 C 24 C 20 C 24 C...
Page 44: ...6 Display content or position may be di aux button...
Page 45: ...W R G W R O G W R LED LED W R O LED LED 7...
Page 48: ...9 F 5 6 7 OFF CLOCK 8 TIMER ON 2 1 0 5 10 0 5 1 2 TIMER ON TIMER ON...
Page 51: ...12 1 ON OFF 2 MODE 3 4 FAN 5 1 Sleep 2 TIMER ON TIMER OFF 3 LIGHT 4 Turbo...
Page 52: ...13 1 2 7 1 5V 3 8...
Page 53: ...13 AUX aux...
Page 54: ...14 1 2 3 4 3 45 C...
Page 55: ...15 1 2 3 4 service 5 service 1 2 1 2...
Page 57: ...17 3 AUTO MODE AUTO 16 C 30o C...
Page 58: ...18...
Page 59: ...19 E5 E8 U8 H6 C5 F1 F2...
Page 60: ...20 250cm 15cm 300cm 15cm 15cm...
Page 61: ...21 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 2 3 4 5 6 2 5 7 8...
Page 62: ...22 1 2 3 4 5 6 7 8 9 1 2 3 4 5 3...
Page 63: ...23 55mm 55mm QD 55mm 55mm QB 1 2 3 ST4 2X25TA 1 2 55 70 5 10 150mm 150mm 150mm 150mm...
Page 64: ...24 5 10 55 1 1 2 3 2...
Page 65: ...25 2 1 m 6 9 52 12 16 19 30 40 45 55 60 65 70 75 15 20 4 1...
Page 66: ...26 N 1 2 3 2 2 3 o y 3mm 4 5...
Page 67: ...27 r 1 2 1 2 3 4 5 3 4...
Page 68: ...28 1 2 ON OFF MODE AUTO COOL DRY FAN HEAT...
Page 73: ......
Page 108: ......