background image

Removing the collected water

There are three ways to remove collected water.

1. Use the bucket

When the unit is off, if the bucket is full, the Full indicator

light will illuminate.

When the unit is on, if the bucket is full, the compressor

and the fan turn off, and the Full indicator light will light,

the digital display shows P2.

Slowly pull out the bucket. Grip the left and right

handles securely, and carefully pull out straight so

the water does not spill. Do not put the bucket on the floor

because the bottom of the bucket is uneven. Doing so will

cause the bucket to fall and the water to spill.

Throw away the water and replace the bucket. The

bucket must be in right place and securely seated for the

dehumidifier to operate.

The machine will re-start when the bucket is restored

in its correct position.

OPERATING  THE  UNIT

NOTES:

    

When you remove the bucket, do not touch any parts

inside of the unit. Doing so may damage the product.

Be sure to push the bucket gently all the way into the

unit. Banging the bucket against anything or failing to

push it in securely may cause the unit not to operate.

If the pump hose drops when you remove the bucket

(see Fig.7),you must reinstall the pump hose properly

to the unit before replace the bucket into the unit

(see Fig.8).

When you remove the bucket, if there is some water in

the unit you must dry it.

When the unit is on, if the bucket is removed, the

compressor and the fan turn off, then the unit will beep

8 times and the digital display shows Eb.

When the unit is off, if the bucket is removed, the unit

will beep 8 times and the digital display shows Eb.

2. Continuous draining

Water can be automatically emptied into a 

drain by attaching the unit with a water hose

(Id    5/16 , not included) with a female threaded

end (ID:M=1  , not included)

8

 

Remove the plastic cover from the back drain outlet of 

the unit and set aside, then insert the drain hose through

the drain outlet of the unit and lead the drain hose to

and Fig.10)

When you remove the plastic cover, if there is some 

water in the back drain outlet of the unit you must dry it.

Make sure the hose is secure so there are no leaks and

the end of the hose is level or sloping downward allowing 

the water to flow smoothly.

Direct the hose toward the drain, making sure that

there are no kinks that will stop the warter flow.

NOTE: When the continuous draining feature is not being used,remove the drain hose from the outlet,

and dry the water in the continuous drain hose outlet.

Select the desired humidity setting and fan speed on the 

unit for continuous draining to start.

Removing the collected water

NOTE: When the continuous draining feature is not being used, remove the drain hose from

the outlet, and dry the water in the continuous drain hose outlet.

3. Pump draining (on some models)

Water can be automatically emptied into a floor

drain by attaching

the pump drain out with a pump drain hose

( od=1/4 , supplied).

Remove the continuous drain hose fromthe unit and install

the plastic cover to the continuous drain hose outlet of the

unit by clockwise rotation.(See Fig.11).

Resert the pump drain hose into the pump drain hose

outlet for depth of 15mm at least (See Fig.11), then lead

the water hose to the floor drain or a suitable drainage facility.

Press the pump pad of the unit to activated the pump

operation. When the bucket is full the pump starts to work.

NOTE: The pump may cause a loud noise when it starts to

work for 3~5 minutes, this is normal.

Make sure the hose is secure so there are no leaks.

Direct the hose toward the drain, making sure that there

are no kinks that will stop the warter flow.

Place the end of the hose into the drain and make sure

the end of the hose is level or sloping downward allowing

 the water to flow smoothly.Never have the water flow upwards.

Select the desired humidity setting and fan speed on the

unit for pump draining to start.

NOTE: The pump operation on light blinks at 1Hz when the

pump is in operational failure. Please turn off the unit and unplug

the power cord. Check the following things:

Cleaning the filter of the pump.

Remove the bucket from the unit, take down the pump

and clean the filter of the pump (See Fig.12).

Check that the pump drain hose is not kinked or blocked.

Empty the water of the bucket.

Reinstall the pump hose if it drops and reinstall the bucket

properly. Turn on the unit. If the error repeats, call for service.

OPERATING THE UNIT

NOTE: Do not use this operation when the outdoor temperature

is equal to or less than 0 C (32 F),otherwise the water becomes ice

and this may cause the water hose to get blocked up which may

cause the unit to fail.

Make sure to empty the bucket once a week when using

the pump draining feature. When the pump draining feature is

not being used, remove the pump drain hose from the outlet.

Press the pump drain hose outlet in and take the pump drain hose

out from it (See Fig.13). Make sure to not let the water in the pump

hose drip onto the floor.

    

Pump drain

hose

Pump drain

hose outlet

    

Filter of the pump

    

    

    

    

    

    

    

OPERATING  THE  UNIT

2,Take the pump 

drain hose out

1,Press the pump drain

hose outlet in

Fig.11

Reinstall the

plastic cover

Fig.13

9

Summary of Contents for P2 - WiFi25L

Page 1: ...s Manual Dezumificator Manual de Utilizare ENG GR RO Thank you for choosing INVENTOR this unit please read this manual carefully and keep it for future reference P2 WiFi25L INVENTOR E L E C T R I C A...

Page 2: ...t a little preventive care on your part can save you a great deal of time and money over the life of your dehumidifier You will find many answers to common problems in the chart of Troubleshooting Tip...

Page 3: ...may cause failure of the appliance or an accident Water may spill inside the unit causing insulation failure and electrical shock or fire There is danger of fire or electric shock You may be injured i...

Page 4: ...he button tochange operation modes theunit will make a beep soundto indicate thatit is changing modes Humidity Set Control Pads Up Down Pads TIMER Set Control Pads Use the Up Down pads to set the Auto...

Page 5: ...Do not force casters to move over carpet nor move the unit with water in the bucket The unit may tip over and spill water Adehumidifier operating in a basement will have little or no effect in drying...

Page 6: ...outlet Select the desired humidity setting and fan speed on the unit for continuous draining to start Removing the collected water NOTE When the continuous draining feature is not being used remove th...

Page 7: ...ck that the pump hose is not kinked or blocked Empty the water of the bucket 3 Clean the air filter Remove the filter every two weeks based on normal operating conditions To remove the filter pull fil...

Page 8: ...rranty that corresponds to the product in your possesion Fill in the required information owner retailer and appliance and press send You will receive a con rmation e mail for the activation of your w...

Page 9: ...A B 1 8 2 2 3 4 5 6 7 7 8 10 11...

Page 10: ...2 3 15...

Page 11: ...5 RH 5 250 3 WiFi AP WiFi router 8 WiFi WiFi 8 WiFi UP Down 0 0 24 35 85 0 24 5 35 RH 90 RH AS ES P2 EC EC E3 Eb 3 3 3 250 Timer Timer o Timer on Timer Timer on Timer o UP DOWN 10 24 5 0 0 P2 On Off F...

Page 12: ...6 7 2 3 1 2 3 4 5 1 2 3 4 20cm 20cm 40cm 20cm 40cm 4 1 1 Power 40 Power 50 5 2 6 7 3 20cm 40cm 5 o C 24 5o C 35 C 220 240V 50Hz...

Page 13: ...1 2 2 3 1 5 Fig 6 3 2 8 9 7 8 10 3 Power 40 Power 50 0 C 2 1 13 11 13 9 P2 7 8 8 Eb 8 Eb 13 5mm 9 10 6 35mm 11 15mm 11 3 5 1Hz 12...

Page 14: ...5 C ES AS P2 EC Eb 3 10 1Hz 3 2 14 1 4 1 2 14 11...

Page 15: ...5 site http www inventoraircondition gr egiisi inventor e mail http www inventoraircondition gr egiisi inventor Inventor...

Page 16: ...bani pe durata de via a aparatului dac acorda i aten ie preventiv n ngrijirea aparatului Ve i g si multe r spunsuri la problemele comune n graficul de sfaturi de depanare Dac examina i diagrama noastr...

Page 17: ...i i pot provoca un incendiu Exist risc de oc electric sau incendiu Nu acoperi i priza sau orificiile de evacuare cu c rpe sau prosoape Lipsa aerului poate conduce la supra nc lzire i incendiu C nd cur...

Page 18: ...cand aparatul se opre te nu poate fi repornit dec t dupa trecerea a 3 minute n acest fel aparatul este protejat Func ionarea va fi reluat automat dup 3 minute Setarea timpului C nd aparatul func ione...

Page 19: ...dea sub 50C 410F Rolele pot fi acoperite cu ghea la o temperatur sub 50C 410F ceea ce poate afecta func ionarea A eza i aparatul departe de usc torul de haine nc lzitor sau radiator Folosi i aparatul...

Page 20: ...umiditate i viteza ventilatorului pentru a ncepe NOT Func ionarea pompei clipe te la 1Hz atunci c nd pompa nu este opera ional V rug m s opri i aparatul i deconecta i cablul de alimentare de la re ea...

Page 21: ...umidificatorul nu usuc aerul a a cum ar trebui Aparatul scoate un zgomot mare c nd func ioneaz Se formeaz ghea pe bobine Apare ap pe podea ES AS P2 EC Eb sau E3 APARE PE ECRAN Ledul de la PUMP afiseaz...

Reviews: