INVENTOR MOB-GPC09AH Owner'S Manual Download Page 13

9

 

1. After powered on, press ON/OFF button, the unit will start to run.(Note: When

it is powered off, the guide 

louver of main unit will close automatically.)

2. Press MODE button, select desired running mode, or press COOL or HEAT

 

 

mode to enter into the corresponding 

operation directly.

3. Pr or - button, to set the desired temperature. (It is unnecessary 

to 

set the temp. at AUTO mode.)

4. Pressing FAN button, set fan speed, can select AUTO, FAN 1, FAN 2, 

FAN 3 or FAN 4.

5. Pressing SWING button, to select the swing.

1. Press SLEEP button, to set sleep.

2. Press TIMER button, can set the scheduled timer on or timer off.

Guide for operation- General operation

Guide for operation- Optional operation

1.   

4.

2.
3.

Slightly to press the place         to take out the back cover of wireless 

remote control.(As shown in figure)

Take out the old batteries. (As show in figure)
 Insert two new AAA1.5V dry batteries, and pay attention to the polarity. 

 (As show in figure)
 Attach the back cover of wireless remote control. (As show in figure)

When changing the batteries, do not use the old or different batteries,

If the wireless remote control will not be used for a long time, please 

otherwise, it can cause the malfunction of the wireless remote control.

take them out, and don't let the leakage liquid damage the wireless 

remote control.

The operation should be in its receiving range.
It should be placed at where is 1m away from the TV set or stereo sound sets.
If the wireless remote control can not operate normally, please take them out, 

 after 30s later and reinsert, if they cannot normally run, please change them.

NOTE:

Changing batteries and notices

Summary of Contents for MOB-GPC09AH

Page 1: ...MOBILE AIR CONDITIONER MOB GPC09AH...

Page 2: ......

Page 3: ...0 6 ACCESSORIES AND INSTALLATION OF HEAT EXHAUST HOSE 12 7 MAINTENANCE 14 Names and functions of wireless remote control 7 Guide for operation General operation 9 MALFUCTION ANALYSIS 15 SAFE NOTE AND...

Page 4: ...Thank you for your selection please read this instruction carefully before operating and keep it for consultation...

Page 5: ...the unit This instruction is only for reference the specification parameters are subject to be changed without notice evaporator fluel capillary flue2 condenser cool air fan motor heat air Under func...

Page 6: ...r will enter to maintain balance air pressure thus the air conditioner will only lower temperature of partial re gional air of indoor room instead of turning entire indoor air to a lower temperature U...

Page 7: ...Rear Air outlet vent Upper air inlet grille Lower air inlet grille Control panel Guide louver Swing louver Wheel Power Filters Remote conrtoller box cord Front STRUCTURE 3...

Page 8: ...or copper and capacity for fuse should be pro per it is forbidden to fix power on blade or sharp objects to prevent creep age leaded by mangled wire Circuitry must be installed and fixed by professio...

Page 9: ...is full We should drain off the water Panel control l 3 MODE In the state of running press the key to enter the mode of COOL DEHUMIDIFY FAN 4 Fan speed Turn on or turn off the unit press once to turn...

Page 10: ...layed and is not adjusable High Medium or low symbol will be displayed in display window according to speed of indoor fan Environmental temperature Usage environmental temperature of this unit is 16 3...

Page 11: ...e selected After powered on Sleep SLEEP button SLEEP Off is defaulted After the unit is turned off the Sleep function is canceled After Sleep function set up the signal of Sleep will display In this m...

Page 12: ...y pressing this key under switch off state you may set the time for auto switch on The TIMER button TIMER range of setting is 0 5 24 hours The characters T ON and H will flash for 5 seconds Within 5 s...

Page 13: ...press the place to take out the back cover of wireless remote control As shown in figure Take out the old batteries As show in figure Insert two new AAA1 5V dry batteries and pay attention to the pola...

Page 14: ...ow and whole unit stop running Plug out plug on drainage Install of drainage hose as shown in following figure Note Drainage hose must be installed before using otherwise block of drain may occur and...

Page 15: ...e into the exhaust adapter 3 Twist clockwise to lock hose into place 4 Insert the other end of the flexible exhaust hose into the window exhaust adapter 5 Twist clockwise to lock hose into place A Dra...

Page 16: ...installing exhaust pipe should be as flat as possible Don t prolong the pipe or connect it with other exhaust pipe or Correct installation is as shown in figure When installing it on wall height of h...

Page 17: ...cm 55cm If the pipe are to be bent please install it by considering Wrong installation is shown in following figure If the pipe is following dimension bent too much it would easily cause malfunction 1...

Page 18: ...s Mobile AC Warning Clean air filter Please soak the cloth by warm whose temperature is lower than 40 or soap water or water with proper cleaner and wipe the dirty part on unit slightly after the clot...

Page 19: ...ator frosts 1 The evaporator frosts 1 Low voltage over current The water tank gets full Solutions 1 Insert the power plug tightly 2 Replace the power plug or socket 3 Ask for the maintenance man to re...

Page 20: ...taken lot of soporific Don t climb on the unit or place something on it for drop may occur and le ading malfunction Don t let wind blows to human directly for long time for it is not good for health...

Page 21: ...ronic waste can be disposed of at least free of charge to the user b When buying a new product the retailer will take back the old product at least free of charge c The manufacturer will take back the...

Page 22: ......

Page 23: ......

Page 24: ...66129910245...

Reviews: