INVENTOR MOB-GPC09AH Owner'S Manual Download Page 11

Names and functions of wireless remote control

ON/OFF button

ON/OFF

Remote control

Signal transmitter




AUTO
COOL
DRY
FAN
HEAT

(Only for cooling and heating unit.)

Fan 2

Fan 1
Fan 3

Fan 4

Don't drop or throw the remote control; Don't let any liquid in the remote control and

Note: Be sure that there are no obstructions between receiver and remote controller;

put the remote control directly under the sunlight or any place where is very hot.

Press this button, Auto, Cool,Dry, Fan,

Heat mode can be selected circularly. 

MODE button

MODE

Auto mode is default while power on. 

Under Auto mode,the temperature will not 
be displayed; Under Heat mode, the
initial value is 28

;Under other 

modes, the initial value is 25

.

Press this button, Sleep On and Sleep 

Off can be selected. After powered on,Sleep

SLEEP button

SLEEP

Off is defaulted. After the unit is turned 

off, the Sleep function is canceled. After
Sleep function set up, the signal of Sleep
will display. In this mode, the time of timer

can be adjusted. Under Fan and Auto 
modes, this function is not available.

 

B

y pressing this key, 

you may select AUTO, 

FAN 1, FAN 2, FAN 3

 or FAN 4, and may 

FAN button

FAN

cool mode.

 After being energized, AUTO 

is 

defaulted. 

Only LOW fan can be set 

(

o

F)

82

(

o

F)

77

Press this button, the unit will be turned on, 

press it once more, the unit will be turned

off. When turning on or turning off the unit,

the Timer, Sleep function will be canceled,

but the presetting time is still remained.

not 

adjust the fan 

speed, but can send 

message. 

under 

DRY

 mode

,

pressing this key can 

 

also cycle between

 them. FAN 4 only in 

 

SWING button

SWING

Press this key to activate or deactivate

 the swing.

AUTO

COOL

DRY

FAN

HEAT

Operation of wireless remote control

7

Summary of Contents for MOB-GPC09AH

Page 1: ...MOBILE AIR CONDITIONER MOB GPC09AH...

Page 2: ......

Page 3: ...0 6 ACCESSORIES AND INSTALLATION OF HEAT EXHAUST HOSE 12 7 MAINTENANCE 14 Names and functions of wireless remote control 7 Guide for operation General operation 9 MALFUCTION ANALYSIS 15 SAFE NOTE AND...

Page 4: ...Thank you for your selection please read this instruction carefully before operating and keep it for consultation...

Page 5: ...the unit This instruction is only for reference the specification parameters are subject to be changed without notice evaporator fluel capillary flue2 condenser cool air fan motor heat air Under func...

Page 6: ...r will enter to maintain balance air pressure thus the air conditioner will only lower temperature of partial re gional air of indoor room instead of turning entire indoor air to a lower temperature U...

Page 7: ...Rear Air outlet vent Upper air inlet grille Lower air inlet grille Control panel Guide louver Swing louver Wheel Power Filters Remote conrtoller box cord Front STRUCTURE 3...

Page 8: ...or copper and capacity for fuse should be pro per it is forbidden to fix power on blade or sharp objects to prevent creep age leaded by mangled wire Circuitry must be installed and fixed by professio...

Page 9: ...is full We should drain off the water Panel control l 3 MODE In the state of running press the key to enter the mode of COOL DEHUMIDIFY FAN 4 Fan speed Turn on or turn off the unit press once to turn...

Page 10: ...layed and is not adjusable High Medium or low symbol will be displayed in display window according to speed of indoor fan Environmental temperature Usage environmental temperature of this unit is 16 3...

Page 11: ...e selected After powered on Sleep SLEEP button SLEEP Off is defaulted After the unit is turned off the Sleep function is canceled After Sleep function set up the signal of Sleep will display In this m...

Page 12: ...y pressing this key under switch off state you may set the time for auto switch on The TIMER button TIMER range of setting is 0 5 24 hours The characters T ON and H will flash for 5 seconds Within 5 s...

Page 13: ...press the place to take out the back cover of wireless remote control As shown in figure Take out the old batteries As show in figure Insert two new AAA1 5V dry batteries and pay attention to the pola...

Page 14: ...ow and whole unit stop running Plug out plug on drainage Install of drainage hose as shown in following figure Note Drainage hose must be installed before using otherwise block of drain may occur and...

Page 15: ...e into the exhaust adapter 3 Twist clockwise to lock hose into place 4 Insert the other end of the flexible exhaust hose into the window exhaust adapter 5 Twist clockwise to lock hose into place A Dra...

Page 16: ...installing exhaust pipe should be as flat as possible Don t prolong the pipe or connect it with other exhaust pipe or Correct installation is as shown in figure When installing it on wall height of h...

Page 17: ...cm 55cm If the pipe are to be bent please install it by considering Wrong installation is shown in following figure If the pipe is following dimension bent too much it would easily cause malfunction 1...

Page 18: ...s Mobile AC Warning Clean air filter Please soak the cloth by warm whose temperature is lower than 40 or soap water or water with proper cleaner and wipe the dirty part on unit slightly after the clot...

Page 19: ...ator frosts 1 The evaporator frosts 1 Low voltage over current The water tank gets full Solutions 1 Insert the power plug tightly 2 Replace the power plug or socket 3 Ask for the maintenance man to re...

Page 20: ...taken lot of soporific Don t climb on the unit or place something on it for drop may occur and le ading malfunction Don t let wind blows to human directly for long time for it is not good for health...

Page 21: ...ronic waste can be disposed of at least free of charge to the user b When buying a new product the retailer will take back the old product at least free of charge c The manufacturer will take back the...

Page 22: ......

Page 23: ......

Page 24: ...66129910245...

Reviews: