background image

DEHUMIDIFIER - AIR PURIFIER

MODELS:

CF-WUHI-16L

CF-WUHI-20L

• USER’S MANUAL

• ΕΓΧΕΙΡΙΔΙΟ ΧΡΗΣΗΣ

• MANUALUL UTILIZATORULUI

ENGLISH | ΕΛΛΗΝΙΚΑ | ROMANA 

Summary of Contents for CF-WUHI-16L

Page 1: ...DEHUMIDIFIER AIR PURIFIER MODELS CF WUHI 16L CF WUHI 20L USER S MANUAL MANUALUL UTILIZATORULUI ENGLISH ROMANA...

Page 2: ...LANGUAGES ENGLISH 3 33 ROMANA 65...

Page 3: ...T R290 26 Dear Consumer Congratulations on your choice Comfort dehumidifier series is an innovative device that ensures both dehumidifying and purifying capabilities with a premium performance It s du...

Page 4: ...people with the lack of knowledge and experience must be supervised depending the situation by persons responsible for their well being and do not undertake procedures such as the cleaning or the mai...

Page 5: ...r runners etc Cord should be arranged away from areas where accidental tripping may occur l Casters should be able to move comfortably over any obstacle Be extra cautious while moving over carpets sin...

Page 6: ...Power off the dehumidifier before removing the plug 3 SOCIABLE REMARKS ENVIRONMENTAL PROTECTION Disposal of equipment no longer used Please follow the instructions below when using this dehumidifier...

Page 7: ...ean environmental directives l Do not penetrate in any way or burn l The maintenance and repairs that require the assistance of qualified personnel should be carried out under the supervision of infla...

Page 8: ...al number placed on the device Please refer to the electronic warranty instructions in the last page English section of this manual 5 STEPS BEFORE USE User s manual Dehumidifier Air Purifier with Comp...

Page 9: ...Place the unit in an area where the temperature levels will not fall bellow 5 C 41 F There is a possibility the coils will collect frost at temperatures that are under 5 C 41 F which may result in lo...

Page 10: ...YOUR DEHUMIDIFIER Air Filter HEPA Filter Power Cord Air outlet Handle both sides Air Intake Grill Drain hose outlet Water tank handle Water level indicator Removable water tank Control Panel Casters H...

Page 11: ...r When this operation is selected the indications will appear on the digital display The air purification indication will be slowly flashing while the dehumidification indication will be continuously...

Page 12: ...you can select between four different modes The available modes are Manual mode Smart Dehumidification SMD mode Sleep mode and Dry Clothes mode Manual mode Under manual mode the desired operating cond...

Page 13: ...vent of a power failure the unit will restart the drying clothes process from the beginning For better results place the device in a small room and set nearby the clothes rack Keep doors shut and allo...

Page 14: ...s selected wait for 3 seconds without pressing anything and the indication of timer will appear on the digital display to confirm that timer is activated For auto STOP the device should be left conti...

Page 15: ...ng pressing the OPERATION button for 3 seconds the antibacterial function will be selected After the completion of each operation the device will not turn off but instead the antibacterial function wi...

Page 16: ...activated on the digital panel of the device once 2160 operational hours have been completed When this indication appears the HEPA filter should be replaced with a new one After the replacement of the...

Page 17: ...ected In the event of a power failure the device performs Auto Restart once power is restored In case of power failure or when the power plug unplugged from the socket the unit will operate in default...

Page 18: ...sible to the router during the pairing process Step 1 Download and install the Inventor Control application from the Google Play Store or IOS App Store Step 2 Select Register to create a new account o...

Page 19: ...ing this step Troubleshooting If the pairing process is not successful l Verify that the router is broadcasting at 2 4GHz l If the router has dual band broadcasting verify that the network names SSIDs...

Page 20: ...re installed the unit will automatically restart When you remove the tank do not touch any parts inside the unit as you may damage the device Be sure to gently place the tank into the dehumidifier Do...

Page 21: ...21 EN Caution water hose should never be bend or twisted When the continuous drainage feature is not being used remove the drain hose from the drain hose outlet and re install the rubber cap x x...

Page 22: ...Make sure that the air filter is dry and refitted correctly Do not bend the filter and ensure it is fitted before operating the unit l Cleaning the tank Remove the plastic protective lid and partiall...

Page 23: ...a dehumidifier may lower energy costs Where should the dehumidifier be placed ideally For optimal results it is suggested that the dehumidifier is placed in a central area Doors within the household...

Page 24: ...to dry clothes depend on many factors the room s temperature the humidity level the moisture of the clothes etc so there is no standard time since of these variable factors mentioned above Poor perfo...

Page 25: ...enough l Make sure you have cleaned the filter as suggested Clogged filter may result in reduced performance l All house exits windows doors etc where the dehumidifier is operating should be shut l Ro...

Page 26: ...itions within the area have been made safe by control of flammable material 3 Checking for presence of refrigerant The area shall be checked with an appropriate refrigerant detector prior to and durin...

Page 27: ...cks shall include that capacitors are discharged this shall be done in a safe manner to avoid possibility of sparking that there no live electrical components and wring are exposed while charging reco...

Page 28: ...d which requires brazing all of the refrigerant shall be recovered from the system or isolated by means of shut off valves in a part of the system both before and during the brazing process 14 Removal...

Page 29: ...scales before recovery takes place g Start the recovery machine and operate in accordance with manufacturer s instructions h Do not overfill cylinders No more than 80 volume liquid charge i Do not exc...

Page 30: ...an acceptable level to make certain that flammable refrigerant does not remain within the lubricant The evacuation process shall be carried out prior to returning the compressor to the suppliers Only...

Page 31: ...The design and the specifications of the product for reasons such as product improvement are subject to change without any prior notice Please consult with the manufacturer at 30 211 300 3300 or with...

Page 32: ...or l Fill all the fields as shown below once the warranty submission has been completed a confirmation message will be sent to your email Full Name Address Postal Code Phone Number E mail Unit Type Se...

Page 33: ...33 GR 1 34 2 36 3 36 4 R290 37 5 38 6 40 7 41 8 48 9 INVENTOR CONTROL 50 10 52 11 54 12 55 13 55 14 R290 58 Comfort Comfort...

Page 34: ...34 GR 1 l 220 240V 50Hz l l l 30 l l l l l l l 8 l l l l l l l l l...

Page 35: ...35 GR l l l l l l l l l l l l l l l 24...

Page 36: ...36 GR 2 l l l l l l l l PCB T 3 15A 250V 350V 3 l 2002 96 EC 27 2003 l CO2 l A B...

Page 37: ...37 GR 4 R290 l l To R290 l l R290 R290...

Page 38: ...38 GR 5 SN D2002255780115715200209 SN D2002255780115715200209 A SN...

Page 39: ...39 GR A 1 30cm 40cm 2 5 C 5 C 5 C 35 C 30 90 3 4 2 5...

Page 40: ...40 GR 6 HEPA...

Page 41: ...41 GR 7 POWER POWER OPERATION OPERATION manual mode sleep mode idle mode manual mode SMD Sleep mode Dry Clothes mode Pantone 7693C Pantone 1797C Control panel backround white...

Page 42: ...42 GR manual mode SMD Sleep mode Dry Clothes mode led 55 56 79 80 45 55 MODE MODE manual mode SMD sleep mode dry clothes mode Manual mode manual mode...

Page 43: ...43 GR Smart dehumidification mode SMD mode 45 55 Sleep mode sleep mode Comfort Dry Clothes mode dry clothes mode 2 45 2 45 2 12 30 50...

Page 44: ...44 GR RH Relative Humidity 40 80 CO 5 manual mode sleep mode CO FAN SPEED FAN SPEED 01 02 03 FAN SPEED 01 02 03 Auto A 01 02 3 H Auto TIMER IMER...

Page 45: ...45 GR 1 1 9 3 timer SWING LOUVER INDICATOR LIGHT Muting Of The Control Panel control panel 3 swing louver indicator light IONIZER 3 swing louver...

Page 46: ...46 GR ULTRAVIOLET TYPE C UVC 3 light indicator ultraviolet UVC led CHILD LOCK timer 3 OPERATION 3 90 90 P1 AUTO DEFROST P1 0 C 12 12 2 C...

Page 47: ...47 GR Auto Defrost P2 P2 P3 P3 360 FAN SPEED 3 P4 HEPA P4 HEPA 2160 90 HEPA PA FAN SPEED 3 HEPA O HEPA 30 Lo 31 Lo 32...

Page 48: ...48 GR 8 O O O TIMER Hi 91 Hi 90...

Page 49: ...outer dual band SSID router l Wi Fi WPA2 PSK AES l router 1 Inventor Control Google Play Store IOS APP Store 2 Register Log in with Existing Account Privacy Policy Agree email email Enter Verification...

Page 50: ...50 GR 4 MODE 3 Confirm wifi LED 5 Wi Fi Confirm l router 2 4 GHz l router dual band SSID router l Wi Fi WPA2 PSK AES l router l router tablet 5 l 2 l tablet l fter Sales Inventor...

Page 51: ...51 GR 10 1 2...

Page 52: ...52 GR x x...

Page 53: ...53 GR 15 11 l o l 2 l HEPA 30...

Page 54: ...54 GR 12 24 13 HEPA 45 55...

Page 55: ...55 GR display 5 C 41 F...

Page 56: ...56 GR l l l l l l l l l l l l l l l l l l l l l l l C1 C2 C8 3 C...

Page 57: ...57 GR POWER 10 14 R290 1 2 3 4 CO2 5...

Page 58: ...58 GR 6 7 8 9...

Page 59: ...59 GR 10 11 12 13 O LFL 25 14...

Page 60: ...60 GR 15 16...

Page 61: ...61 GR 80 17 18...

Page 62: ...62 GR 19 20 21 22...

Page 63: ...63 GR 211 300 3300 www inventoraircondition gr media library...

Page 64: ...inventor QR 2 4 mail email 5 Inventor 3 email email newsletter Inventor l link QR code https www inventoraircondition gr egiisi inventor l email A email newsletter Inventor l email A email newsletter...

Page 65: ...mate consumator Felicitari pentru alegere Seria de dezumidificatoare Comfort este un dispozitiv inovator care asigura atat capacitati de dezumidificare cat si de purificare cu o performanta premium Ut...

Page 66: ...curatare sau mentenanta l Nu permiteti copiilor sa se joace cu acest aparat l Acest aparat se va folosi intr un mediu domestic sau spatiu de birouri Este interzisa folosirea acestui aparat afara in sp...

Page 67: ...re Nu comprimati cablul de alimentare l Nu trageti cablul de alimentare pe sub covoare carpete sau presuri Asezati cablul de alimentare in asa fel incat sa nu va impiedicati de el l Nu impingeti forta...

Page 68: ...e a l scoate din priza 3 OBSERVATII PROTECTIA MEDIULUI Mai jos veti gasi informatii cu privire la procedeul de eliminare a acestui produs cand acesta nu mai este folosit l Eliminarea acestui aparat tr...

Page 69: ...opene cu privire la mediu Acest aparat contine aproximativ 95g agent frigorific R290 l Nu strapungeti si nu utilizati surse de foc in apropierea unitatii l Mentenanta si reparatiile necesita asistenta...

Page 70: ...te in partea din spate a aparatului Va rugam sa faceti referire la certificatul de garantie electronic la ultima pagina sectiunea limbii engleze a acestui manual 5 INAINTE DE FOLOSIRE Manualul utiliza...

Page 71: ...easupra 2 Montati aparatul intr o incapere in care temperatura nu va scadea sub 5 C 41 F Aparatul poate acumula straturi de gheata pe componentele interne ceea ce ii va reduce eficienta Conditii de fu...

Page 72: ...TULUI HEPA Filtru Rotite Grila evacuare aer Water tank handle Water level indicator Panou de control Air Quality Indicator Maner Rezervor de apa detasabil Filtru Grila admisie aer Canal furtun de scur...

Page 73: ...dificarea Cand unitatea functioneaza ca purificator de aer doar modul Manual si modul Sleep pot fi selectat Dezumidificator Functionare ca dezumidificator Cand este selectata aceasta operatiune indica...

Page 74: ...ca nivelul de umiditate din camera este cuprins intre 56 79 Ledul rosu indica faptul ca nivelul de umiditate din camera este peste 80 In functie de conditiile externe nivelurile ideale de umiditate fl...

Page 75: ...e setat de acest mod este de 12 ore si poate fi redusa in functie de dimensiunea camerei si de umezeala hainelor Daca rezervorul de apa se umple in timpul operatiunii inainte de ora stabilita de 2 ore...

Page 76: ...redusa si in modul de Imbracaminte Uscata setat la viteza mare TEMPORIZATOR Apasati butonul TIMER pentru a configura temporizatorul pentru oprire automata De fiecare data cand este apasat acest buton...

Page 77: ...butonului temporizator timp de 3 secunde blocarea pentru copii va fi activata dezactivata automat Indicatorul va ramane constant pe afisaj informand ca blocarea pentru copii este activa Sub Child Lock...

Page 78: ...t corect indicatia P2 va aparea pe panoul de control digital urmat de un semnal sonor P3 ANUNT CURATARE PREFILTRE Cand acest indicator apare pe afisajul digital este un memento ca prefiltrul trebuie i...

Page 79: ...i Dupa Autorestart functia Timer setata anterior nu va ramane salvata Lo Umiditate foarte scazuta Cand umiditatea camerei este 31 RH acest indicator se activeaza pe panoul de control digital al dispoz...

Page 80: ...ere Pasul 1 Descarcati si instalati aplicatia Inventor Control din Google Play Store sau IOS App Store Pasul 2 Selectati Inregistrati va pentru a crea un cont nou sau Conectati va cu contul existent N...

Page 81: ...s l Verificati daca routerul transmite la 2 4GHz l Daca routerul are transmisie cu banda dubla verificati daca numele de retea SSID sunt diferite Pentru ajutor suplimentar contactati furnizorul dvs de...

Page 82: ...ste repozitionat unitatea va reporni Cand scoateti rezervorul nu atingeti nicio parte din interiorul aparatului deoarece il puteti deteriora Asigurati va ca asezati usor rezervorul in dezumidificator...

Page 83: ...83 RO Atentie urtunul nu ar trebui sa fie indoit sau rasucit Cand drenajul continuu nu este utilizat scoateti furtunul de evacuare din orificiul de evacuare si reinstalati capacul de cauciuc x x...

Page 84: ...te uscat si montat corect Nu indoiti filtrul si asigurati va ca este montat inainte de a utiliza unitatea l Curatarea rezervorului Scoateti capacul de protectie din plastic si umpleti partial rezervor...

Page 85: ...cator poate reduce costurile energiei electrice Unde ar trebui sa fie plasat Pentru rezultate optime se sugereaza ca dezumidificatorul este amplasat intr o zona centrata Usile din gospodarie ar trebui...

Page 86: ...a obstacole care blocheaza intrarea iesirea aerului Umiditatea ambientala poate fi mai mica decat setarea de umiditate Verificati daca toate usile ferestrele si altele sunt bine inchise Temperatura ca...

Page 87: ...nd functioneaza l Filtrul de aer este infundat l Dispozitivul este inclinat in loc sa fie in pozitie verticala l Suprafata nu este plana Inghet se formeaza pe bobine lAcest lucru este normal Aceasta u...

Page 88: ...stuia echipamentul adecvat de stingere a incendiilor va fi la indemana Este necesara o pulbere uscata sau extinctor cu CO2 adiacent zonei 5 Nu exista surse de aprindere Nicio persoana care efectueaza...

Page 89: ...nexiunilor bornele care nu sunt conforme cu specificatiile originale deteriorarea sigiliilor montarea incorecta etc Asigurati va ca sigiliile sau materialele de etansare nu s au degradat astfel incat...

Page 90: ...n ruperea vidului din sistem cu OFN si continuarea umplerii pana la atingerea presiunii de lucru apoi aerisirea in atmosfera si in cele din urma tragerea in jos pana la vid Aceasta procesare se repeta...

Page 91: ...tretinere fie pentru scoaterea din functiune se recomanda ca tot agentul frigorific din cilindri este folosit numai cilindri de recuperare a agentului frigorific corespunzator Asigurati va ca este dis...

Page 92: ...igorifici inflamabili A se vedea reglementarile nationale 21 Depozitarea echipamentelor aparatelor Depozitarea echipamentelor trebuie sa fie in conformitate cu instructiunile producatorului 22 Depozit...

Page 93: ...pot schimba fara o notificare prealabila datorita imbunatatirii continue a echipamentelor noastre Pentru mai multe detalii va rugam sa contactati producatorul la numarul de telefon 30 211 300 3300 sa...

Page 94: ...sau scanati codul QR pentru a va activa garantia pe site ul nostru https www inventoraerconditionat ro certificatul de garantie inventor aer conditionat si electrocasnice l Completati toate campurile...

Page 95: ......

Page 96: ...DEHUMIDIFIER AIR PURIFIER Manufacturer INVENTOR A G S A 24th km National Road Athens Lamia 2 Thoukididou Str Ag Stefanos 14565 Tel 30 211 300 3300 Fax 30 211 300 3333 www inventor ac V 1 0 082021...

Reviews: